INTENDED USE
Your angle grinder D28111/D28113(K)/D28130/
D28132C/D28134/D28135(K)/D28139/D28141 has
been designed for professional grinding and cutting
applications .
DO NOT use under wet conditions or in presence of
flammable liquids or gases.
DO NOT use grinding wheels other than center
depressed wheels and flap-disk.
These heavy-duty angle grinders are professional
power tools. DO NOT let children come into
contact with the tool. Supervision is required when
inexperienced operators use this tool.
1 On/off switch
2 Spindle lock
3 Guard
4 Side handle
D28113(K)/D28130/D28132C/D28135(K)/D28141 -
ANTI-VIBRATION SIDE HANDLE
The anti-vibration side handle offers added comfort
by absorbing the vibrations caused by the tool.
D28113(K)/D28130/D28132C/D28134/D28135(K)/D28141 -
KEYLESS GUARD
The keyless guard allows for quick adjustment during
the application to enhance application versatility.
D28113(K)/D28130/D28132C/D28134/D28135(K)/D28141 -
DUST EJECTION SYSTEM
The dust ejection system prevents dust pile-up
around the guard and motor inlet, and minimises the
amount of dust entering the motor housing.

Electrical safety

The electric motor has been designed for one
voltage only. Always check that the power supply
corresponds to the voltage on the rating plate.
Your D
WALT tool is double insulated in
E
accordance with EN 60745; therefore no
earth wire is required.
WARNING: 115 V units have to
be operated via a fail-safe isolating
transformer with an earth screen between
the primary and secondary winding.

Mains plug replacement

(U.K. & Ireland only)
• Should your mains plug need replacing and you
are competent to do this, proceed as instructed
below. If you are in doubt, contact an authorized
D
WALT repair agent or a qualifi ed electrician.
E
• Disconnect the plug from the supply.
• Cut off the plug and dispose of it safely; a plug
with bared copper conductors is dangerous if
engaged in a live socket outlet.
• Only fi t 13 Amperes BS1363A approved plugs
fi tted with the correctly rated fuse (1).
• The cable wire colours, or a letter, will be marked
at the connection points of most good quality
plugs. Attach the wires to their respective points
in the plug (see below). Brown is for Live (L) (2)
and Blue is for Neutral (N) (4).
• Before replacing the top cover of the mains plug
ensure that the cable restraint (3) is holding the
outer sheath of the cable fi rmly and that the two
leads are correctly fi xed at the terminal screws.
4
3
WARNING: Never use a light socket.
Never connect the live (L) or neutral (N)
wires to the earth pin marked E or
For 115 V units with a power rating exceeding 1500 W,
we recommend to fi t a plug to BS4343 standard.

Using an extension cable

If an extension cable is required, use an approved
extension cable suitable for the power input of this
tool (see technical data). The minimum conductor
size is 1.5 mm
2
.