ARNING Important: For safety purpose, you should read the instructions carefully before using the appliance for the first time. Save the instruction for future reference. The appliance is designed for domestic use and may only be installed and operated in accordance with these instructions for use. **Remove the protection film outside the hood before installation.
Detachable oil cup 1 pc (HC338 / HC768 / HC638 / HE568 / HE438 / HC646) Detachable oil cup 2 pcs (HE2421), oil dish 2 pcs c. Light bulb 1 pc ,water jug x 1 pc (water jug only for HC338 / HC768 / HC638 / HC646) d.
ROCEDURE 1. Find a suitable installation position of hood which Plywood should be next to a window and can be cut to let Exhaust the exhaust duct pass through. duct 2. If the exhaust duct has to pass through the wall, particular attention must be paid to the structure of the wall as steel reinforcement may be embedded.
OUNTING ETHOD Rear mounting (2 brackets are pre-installed) Use 2 screws and 2 washers to secure the hood to the wall. (HC338 / HC768 / HC638 / HE568 / HE438 See FIG.1, HE2421 See FIG.2, HC646 See FIG.3) 586mm 696mm 878mm FIG.1...
PERATION Auto clean and Easy dismantle 2 in 1 cookerhood Model:HC338 Fans On/Off and Delay-off Power Function - Turn on and off the fans. - When auto clean or delay off is enabled, press this button to cancel. Delay Off Function - With the fans on or off, press and hold this button for 3 seconds.
Page 10
PERATION Auto clean and Easy dismantle 2 in 1 cookerhood Model:HC768 Power On/Off - Press once On/Off ( ) button, the appliance will be in stand-by mode. - Press once again, the appliance will be turned off with all function stopped, except the light bulb is an independent control.
Page 11
PERATION Delay Off / Alarm Delay off Press this button once to enable delay off. The default fan speed is 3. The 2 time usage will follow the last memorized fan speed. The default time is 5 minutes. The 2 time usage will follow the last memorized time.
Page 12
PERATION Auto clean and Easy dismantle 2 in 1 cookerhood Model:HC638 / HC646 Power On/Off - Press once On/Off ( ) button, the appliance will be in stand-by mode. - Press once again, the appliance will be turned off with all function stopped, except the light bulb is an independent control.
Page 13
PERATION Delay Off Press this button once to enable delay off. The default fan speed is 3. The 2 time usage will follow the last memorized fan speed. The default time is 5 minutes. The 2 time usage will follow the last memorized time.
Page 14
PERATION Easy dismantle cookerhood Model:HE568 I II I II (1) Display: below is list of each digital display Display Meaning Display Meaning 3.45 3 hours and 45 minutes 0.00 Time is up Alarm / up - When hood is off, press this button to activate the alarm function and set the time.
Page 15
PERATION Easy dismantle cookerhood Model:HE438 / HE2421 I II I II (1) Left fan control - Press ( ) to turn on the left fan at low speed. Press ( ) to turn on the left fan at high speed. Press ( ) to turn off the left fan.
To refer Item 7 to dismount bottom panel and then fasten/loosen light bulb with socket. Note: For HC338 / HC768 / HC638 / HC646 / HE568 / HE438 / HE2421, they can be replaced with 4W max. LED light bulb or 14W max.
THERS 1. Repair service including replacement of main cord should only be carried out by manufacturer, its service agent or a qualified technician. It is dangerous for anyone other than the above mentioned people to perform repair service. 2. Hazardous smoke/fume generated from burning Town gas/L.P. gas or/and cooking must be discharged outside the kitchen through the exhaust pipe.
IRING IAGRAM DUAL MOTOR RANGE HOOD CIRCUIT DIAGRAM BROWN LAMP WATER BLUE PUMP L-MOTOR R-MOTOR PUMP LAMP FUSE 5A Model:HC338S Voltage 220V-240VAC 50Hz Power consumption Total: 171W Max. Lamp: Energy Saving 14W Max. Fan: 157W BODY Serial No. AAE MOTOR MOTOR Date of mfr.
Page 20
IRING IAGRAM DUAL MOTOR RANGE HOOD CIRCUIT DIAGRAM BROWN LAMP BLUE L-MOTOR R-MOTOR WATER LAMP CASE FUSE 5A PUMP Model:HC638W WATER PUMP Voltage 220V-240VAC 50Hz Power consumption Total: 171W Max. Lamp: LED 4W Max. Fan: 157W BODY Serial No. AAE MOTOR MOTOR Date of mfr.
Page 21
IRING IAGRAM DUAL MOTOR RANGE HOOD CIRCUIT DIAGRAM Model:HE438S Voltage 220V-240VAC 50Hz Power consumption Total: 171W Max. Lamp: Energy Saving 14W Max. Fan: 157W Serial No. AAE LAMP BODY MOTOR MOTOR Date of mfr. REMARKS:1. CAPACITOR 2.5μF X 2 450V AC FIT AC220V~240V 50Hz DUAL MOTOR RANGE HOOD CIRCUIT DIAGRAM Model:HE438W Voltage...
線路圖 DUAL MOTOR RANGE HOOD CIRCUIT DIAGRAM BROWN LAMP WATER BLUE PUMP L-MOTOR R-MOTOR PUMP LAMP FUSE 5A Model:HC338S Voltage 220V-240VAC 50Hz Power consumption Total: 171W Max. Lamp: Energy Saving 14W Max. Fan: 157W BODY Serial No. AAE MOTOR MOTOR Date of mfr.
Page 37
線路圖 DUAL MOTOR RANGE HOOD CIRCUIT DIAGRAM BROWN LAMP BLUE L-MOTOR R-MOTOR WATER LAMP CASE FUSE 5A PUMP Model:HC638W WATER PUMP Voltage 220V-240VAC 50Hz Power consumption Total: 171W Max. Lamp: LED 4W Max. Fan: 157W BODY Serial No. AAE MOTOR MOTOR Date of mfr.
Page 38
線路圖 DUAL MOTOR RANGE HOOD CIRCUIT DIAGRAM Model:HE438S Voltage 220V-240VAC 50Hz Power consumption Total: 171W Max. Lamp: Energy Saving 14W Max. Fan: 157W Serial No. AAE LAMP BODY MOTOR MOTOR Date of mfr. REMARKS:1. CAPACITOR 2.5μF X 2 450V AC FIT AC220V~240V 50Hz DUAL MOTOR RANGE HOOD CIRCUIT DIAGRAM Model:HE438W Voltage...