thank you for purchasing a sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
refer to
Wear eye
instructions
protection
1. safety
follow all workshop safety rules, regulations, and conditions when using wrench.
9
warninG! disconnect from air supply before changing accessories or servicing.
maintain the wrench in good condition and replace any damaged or worn parts. use genuine parts only. non-authorised parts
9
may be dangerous and will invalidate the warranty.
warninG! check correct air pressure is maintained and not exceeded. We recommend 90psi.
Keep air hose away from heat, oil and sharp edges. check air hose for wear before each use and ensure that all connections are secure.
9
Only use impact sockets which are specifically designed for use with a ratchet wrench.
9
Wear approved safety eye/face shield, ear defenders, and hand protection.
9
maintain correct balance and footing. ensure the floor is not slippery and wear non-slip shoes.
9
Keep children and non essential persons away from the working area.
9
DO nOt use the wrench for a task it is not designed to perform.
8
warninG! DO nOt use wrench if damaged or thought to be faulty. (contact service Agent).
DO nOt use wrench unless you have been instructed in its use by a qualified person.
8
DO nOt expose the comfort grip to excessive heat.
8
DO nOt carry the wrench by the air hose, or yank the hose from the air supply.
8
DO nOt operate wrench if you are tired, under the influence of alcohol, drugs or intoxicating medication.
8
DO nOt carry wrench with your hand on the power trigger in order to avoid unintentional starting.
8
DO nOt direct air from the air hose at yourself or others.
8
When not in use disconnect from air supply and store in a safe, dry, childproof location.
9
warninG! – risk of Hand Arm Vibration injury.
this tool may cause hand arm Vibration syndrome if its use is not managed adequately.
this tool is subject to the vibration testing section of the machinery directive 2006/42/ec.
this tool is to be operated in accordance with these instructions.
measured vibration emission value (a): ................. 1.7 m/s²
uncertainty value (k): ........................................... 0.85 m/s²
Please note that the application of the tool to a sole specialist task may produce a different average vibration emission. We recommend
that a specific evaluation of the vibration emission is conducted prior to commencing with a specialist task.
A health and safety assessment by the user (or employer) will need to be carried out to determine the suitable duration of use for each tool.
nB: stated Vibration emission values are type-test values and are intended to be typical.
Whilst in use, the actual value will vary considerably from and depend on many factors.
such factors include; the operator, the task and the inserted tool or consumable.
nB: ensure that the length of leader hoses is sufficient to allow unrestricted use, as this also helps to reduce vibration.
the state of maintenance of the tool itself is also an important factor, a poorly maintained tool will also increase the risk of Hand Arm
Vibration syndrome.
Health surveillance.
We recommend a programme of health surveillance to detect early symptoms of vibration injury so that management procedures can be
modified accordingly.
Personal protective equipment.
We are not aware of any personal protective equipment (PPe) that provides protection against vibration injury that may result from the
uncontrolled use of this tool. We recommend a sufficient supply of clothing (including gloves) to enable the operator to remain warm and dry
and maintain good blood circulation in fingers etc. Please note that the most effective protection is prevention, please refer to the correct
use and maintenance section in these instructions. Guidance relating to the management of hand arm vibration can be found on the Hsc
website www.hse.gov.uk - Hand-Arm Vibration at Work.
© Jack sealey limited
instructions for
air ratchet wrenches
model no:
Wear protective
Wear safety
gloves
footwear
Original Language Version
Gsa20.V2, Gsa20Kit.V2,
Gsa21.V2, Gsa21Kit.V2.
Wear protective
Wear ear
clothing
protection
GsA20,GsA20Kit,GsA21,GsA21Kit - V2 | issue 1 15/03/17

Advertisement

loading

Summary of Contents for Sealey GSA20.V2

  • Page 1 Gsa21.V2, Gsa21Kit.V2. thank you for purchasing a sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 4.3.5. The direction of the air flow from the exhaust holes in the central sleeve can be altered by rotating the whole sleeve to a suitable position. the sleeve can be rotated continuously through 360° (see fig.3). Original Language Version GsA20,GsA20Kit,GsA21,GsA21Kit - V2 | issue 1 15/03/17 © Jack sealey limited...
  • Page 3 5.1. if the air system does not have an oiler, lubricate the air wrench daily with a few drops of sealey air tool oil dripped into the air inlet to prolong its life.

This manual is also suitable for:

Gsa20kit.v2Gsa21.v2Gsa21kit.v2