  • Page 1 ACQ580-Px Supplement Installation Manual for ACQ580-PC/PD ACQ580-PC/PD Packaged Drives with Disconnect (1…60 HP)
  • Page 3: Safety Instructions

    Supplemental Installation Manual for ACQ580-Px Safety instructions These are the safety instructions which you • Handle the drive carefully. must obey when you install and operate the • Frames R5…R9: Lift the drive with a drive and do maintenance on the drive. If you lifting device.
  • Page 4: Electrical Safety In Installation, Start-Up And Maintenance

    Supplemental Installation Manual for ACQ580-Px (3AXD50000044862) and Quick Start Guide stop key on the control panel will not stop (3AXD50000049128) for more information. the drive. • Before you connect voltage to the drive, • Frames R1…R5: Do not attempt to repair a make sure that the drive covers are on.
  • Page 5 Supplemental Installation Manual for ACQ580-Px 5. Measure that the installation is Note: For other systems, connecting the de-energized. internal EMC filter will reduce the conducted emission. • Use a multimeter with an impedance of at • If the drive will be connected on a corner- least 1 Mohm.
  • Page 6 Supplemental Installation Manual for ACQ580-Px The boards contain components sensitive to • install a device which automatically electrostatic discharge. disconnects the supply if the protective earth conductor breaks. Grounding These instructions are for all personnel who are responsible for the electrical installation, including the grounding of the drive.
  • Page 7: Additional Instructions For Permanent Magnet Motor Drives

    Supplemental Installation Manual for ACQ580-Px Additional instructions for • Install temporary grounding to the drive output terminals (T1/U, T2/V, T3/W). permanent magnet motor drives Connect the output terminals together as well as to the PE. Safety in installation, start-up and Start-up and operation: maintenance •...
  • Page 8 ABB and its affiliates are not liable for damages and/or losses related to such security breaches, any unauthorized access, interference, intrusion, leakage and/or theft of data or information.
  • Page 9 Made in USA of Foreign Parts Input U1 3ph 400/480 VAC I1 52 A E211945 F1 50/60 Hz FRAME Output U2 3ph 0...U1 ABB Oy Hiomotie 13 I2 52 A 00380, Helsinki f2 0...500 Hz Finland Air cooling IP21 Icc 100 kA...
  • Page 10: Installation

    Supplemental Installation Manual for ACQ580-Px ACQ580-PC/PD Installation This information is unique to ACQ580 input disconnect configurations (PC or PD). The ACQ580 with Input Disconnect is an ACQ580 AC adjustable frequency drive packaged with an input disconnect switch or circuit breaker. Refer to the Installation instructions on page 8, for all other information.
  • Page 11 Supplemental Installation Manual for ACQ580-Px Connection diagrams – Vertical Packaged Drive with input disconnect ACQ580 Vertical Packaged Drive units are configured for wiring access from the bottom only. The following figures show the layout and wiring connection points. For drive control wiring see US Quick Start Guide (3AXD50000049128).
  • Page 12 Supplemental Installation Manual for ACQ580-Px ACQ580 Drive Motor Terminals Motor Ground Lug Fuses Disconnect Switch or Circuit Breaker Input Terminals Input Ground Lug P3/P4 (Px1-3, Px12-3, Px1-4, Px12-4) ACQ580-PC/PD...
  • Page 13 Supplemental Installation Manual for ACQ580-Px Power connection terminals The following tables show maximum wire size and required tightening torque for incoming power, grounding and motor terminals. 1)“Px” represents both PC and PD. Output 208/230 Volt Maximum Power Wiring Data Ratings Base Circuit Disconnect...
  • Page 14 Supplemental Installation Manual for ACQ580-Px 1) “Px” represents both PC and PD. Output 460 Volt Maximum Power Wiring Data Ratings Base Circuit Ground Disconnect Drive Breaker Lugs Switch Frame Motor Type Code Size UL (NEMA) Terminals (NEMA) (NEMA) Type 1 Type 1 Type 1 and 12...
  • Page 15 Supplemental Installation Manual for ACQ580-Px 575 Volt Output Range Maximum Power Wiring Data Base Circuit Ground Drive Breaker Disconnect Lugs Frame Switch UL Motor 1, 2 Type Code UL (NEMA) Size (NEMA) (NEMA) Type Terminals Type 1 Type 1 1 and 12 and 12 and 12 ACQ580-...
  • Page 16 Supplemental Installation Manual for ACQ580-Px Branch circuit protection Input power is connected to the ACQ580 through a door interlocked disconnect switch or circuit breaker. When connected to a 240V or 480V power source, the ACQ580 with the circuit breaker option is suitable for use on a circuit capable of delivering not more than 100,000 RMS symmetrical amperes.
  • Page 17 Supplemental Installation Manual for ACQ580-Px 460 Volt fuses for packaged drive Nominal Output 480 Volt Range Internal Drive External Fuse for Base Fuse Rating Disconnect Option Drive Package Drive Current Power Frame Type Code Size Current Max Current Class Class Rating Rating ACQ580-Px-02A1-4...
  • Page 18: Operation

    Supplemental Installation Manual for ACQ580-Px Operation This information is unique to ACQ580 input disconnect configurations (PC or PD). Refer to the Operation instructions on page for all other information. Input disconnect configuration The ACQ580 with Input Disconnect is an ACQ580 AC adjustable frequency drive packaged with an input disconnect switch or circuit breaker, and with a door interlocked, external operating handle.
  • Page 19 Supplemental Installation Manual for ACQ580-Px Dimensions P1 Type 1 ACQ580-PC/PD...
  • Page 20 Supplemental Installation Manual for ACQ580-Px P1 Type 12 ACQ580-PC/PD...
  • Page 21 Supplemental Installation Manual for ACQ580-Px P2 Type 1 ACQ580-PC/PD...
  • Page 22 Supplemental Installation Manual for ACQ580-Px P2 Type 12 ACQ580-PC/PD...
  • Page 23 Supplemental Installation Manual for ACQ580-Px P3 Type 1 ACQ580-PC/PD...
  • Page 24 Supplemental Installation Manual for ACQ580-Px P3 Type 12 ACQ580-PC/PD...
  • Page 25 Supplemental Installation Manual for ACQ580-Px P4 Type 1 ACQ580-PC/PD...
  • Page 26 Supplemental Installation Manual for ACQ580-Px P4 Type 12 ACQ580-PC/PD...
  • Page 28 ABB Inc. 16250 West Glendale Drive New Berlin, WI 53151 Telephone +1 800 752-0696 +1 262 785-0397 Internet www.abb.com/drives...