This product contains a chemical or chemicals known to the State of California to
Safety
WARNING
Chemical substances used in the spray system may be hazardous and toxic to you, bystanders, animals,
plants, soils, or other property.
• Carefully read and follow the chemical warning labels and material safety data sheets (MSDS) for all
chemicals used and protect yourself according to the chemical manufacturer's recommendations. For
example, use appropriate personal protective equipment (PPE), including face and eye protection,
gloves, or other equipment to guard against personal contact with a chemical.
• There may be more than 1 chemical used and information on each chemical should be assessed.
• Refuse to operate or work on the sprayer if this information is not available.
• Before working on a spray system, ensure that the system has been triple rinsed and neutralized
according to the recommendations of the chemical manufacturer(s) and that all the valves have been
cycled 3 times.
• Verify that there is an adequate supply of clean water and soap nearby, and immediately wash off any
chemicals that contact you.
Installation
Loose Parts
Use the chart below to verify that all parts have been shipped.
Description
Pressure transducer
Cap fitting
Flange gasket
Flow meter
Flow meter gasket
Switch
Wire harness
© 2016—The Toro® Company
8111 Lyndale Avenue South
Bloomington, MN 55420
®
5800 Turf Sprayer
WARNING
CALIFORNIA
Proposition 65 Warning
cause cancer, birth defects, or reproductive harm.
Qty.
1
1
1
1
2
1
1
Register at www.Toro.com.
Install the kit.
Original Instructions (EN)
All Rights Reserved *3405-472* A
Printed in the USA
Form No. 3405-472 Rev A
Installation Instructions
Use

Advertisement

loading

Summary of Contents for Toro 41642

  • Page 1 Form No. 3405-472 Rev A ExcelaRate Upgrade Kit Multi Pro ® 5800 Turf Sprayer Model No. 41642 Installation Instructions WARNING CALIFORNIA Proposition 65 Warning This product contains a chemical or chemicals known to the State of California to cause cancer, birth defects, or reproductive harm.
  • Page 2: Installing The Kit

    Installing the Kit 1. Position the sprayer on a level surface, set the parking brake, stop the pump, stop the engine, and remove the key from the starter switch. 2. Disconnect the negative (-) battery cable from the battery. 3. Loosen the worm clamps that secures the manifold coupler to the agitation valve and section valve assembly (Figure...
  • Page 3 9. Remove the plug from the dashboard (Figure Figure 4 1. Switch 2. Plug 10. Install the switch into the hole (Figure 11. Beneath the dashboard, connect the wire harness to the switch, then connect it to the machine wire harness. Note: The connector on the machine wire harness is tied back to the machine wire harness.
  • Page 4: Operation

    Operation Using the ExcelaRate Software Note: You can use the software immediately after installing the kit. InfoCenter Home Screen Note: The following figure is an example screen; this screen is meant to show all of the potential icons that could appear When you start the machine, the home screen appears, on the screen while operating.
  • Page 5 InfoCenter Main Menu Screen Active-Application Rate The active-application rate indicates the actual rate at which Press and hold the button 5 (far right) on the InfoCenter to the sprayed product is being applied (Figure access the Main Menu screen. From the Main Menu screen, you can access the Set Rates Target-Application Rate screen, Settings screen, Calibration screen, Service screen, Diagnostics screen, or the About screen...
  • Page 6 Note: From the home screen, press and hold buttons Set Rates Screen 1 and 2 simultaneously to select Rate 1 or press and To access the Set Rates screen, press button 2 on the Main hold buttons 4 and 5 simultaneously to select Rate 2. Menu screen (Figure 6) until you reach Set Rates and press...
  • Page 7 Figure 10 Figure 11 Note: Volume indicates the current amount of Change the InfoCenter protected menus as follows: liquid in the tank. The low-limit setting alerts you 1. Press button 2 on the Display settings screen until you when the tank volume has fallen below the specified reach Protected Menus, then press button 4 to select low-limit-tank volume.
  • Page 8 Figure 13 Figure 15 Turn the InfoCenter PIN on/off as follows: 1. Digit 1 4. Digit 4 2. Digit 2 5. Enter PIN 1. Press button 2 on the Display settings screen until you reach PIN Settings, then press button 4 to select PIN 3.
  • Page 9 Figure 17 Figure 19 4. Enter your old PIN using buttons 1 to 4 and press 1. Digit 1 4. Digit 4 button 5 when you complete the PIN (Figure 15). 2. Digit 2 5. Enter PIN 3. Digit 3 Note: The default PIN when you initially create your PIN is 1234.
  • Page 10 Note: It is recommended to start the 15 second catch Boom-Width Settings test at 2.75 bar (40 psi), then adjust from there. The boom-width settings are pre-populated at the All boom sections must be on when performing the manufacturing plant (Figure catch test.
  • Page 11 Service Screen To access the Service screen, press button 2 on the Main Menu screen (Figure 6) until you reach Service, and press button 4 to select Service. Note: While spraying, you can view your current flow rate from the Service screen. G034324 Figure 22 1.
  • Page 12 InfoCenter Spray-Area Screens Diagnostics Screen To access the Diagnostics screen, press button 2 on the Main From the Home screen, press and hold button 5 to open Menu screen (Figure 6) until you reach Diagnostics, and press the menu bar and select the Total Area or Sub-Area screen button 4 to select Diagnostics.
  • Page 13 Figure 28 Sub-Area Screen 1. Active sub-area 4. Volume sprayed in the active sub-area (US gallons) 2. Area sprayed in the active 5. Select the previous sub-area (acres) sub-area; hold the button to reset area and volume sprayed for the active sub-area.
  • Page 14 InfoCenter Advisories Operator advisories automatically display on the InfoCenter screen when a machine function requires additional action. For example, if you attempt to start the engine while pressing the traction pedal, an advisory displays, indicating that the traction pedal must be in the N position.
  • Page 15 Parameter Status A value is outside the range of Parameter status, invalid data accepted values defaults used Booms Turned Off Speed dropped Booms turned off, stopped or moving too slowly...