Philips FM92E Manual page 36

Conversion to 6 meters
Table of Contents

Advertisement

NOTE: Be care-full, when you press the microphone button, you can transmit 5 watts.
As a final test, with channel 20 setup on the FM92E connect your signal generator to 53.000 MHz. You should
hear a signal through the FM92E with approximately 100 mVolt of signal.
NOTE: If the VCO will not tune properly or the transmitter side will not come within voltage range, then check
that pin 19 of the VCO module is 0 Volts on receive and 10 Volts on transmit.
VCO Tune Check References:
Ch # Rx Freq
Injection Frequency
21.4MHz 10.7MHz
3
70.000MHz
10
77.000MHz
98.4MHz
20
53.000MHz
74.4MHz
20
53.000MHz
Philips FM92E Conversion to 6 Meters:
VCO Voltage
Rx
80.7MHZ
5.3v
9.6V 12.0V
63.7MHz
Tx
4.7V
Not Converted
Not Converted
Version 3.9
Page 36