Download Print this page

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions
and maintained properly, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT
CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL
INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
REFER TO
GENERAL
INSTRUCTIONS
WARNING
1. SAFETY
1.1.
ELECTRICAL SAFETY
 WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other
connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. A
Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a Residual Current
Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected by
an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer.
You must also read and understand the following instructions concerning electrical safety.
1.1.1. The Electricity at Work Act 1989 requires that all portable electrical appliances, if used on business premises, are tested by a
qualified electrician, using a Portable Appliance Tester (PAT), at least once a year.
1.1.2. The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances
and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.
1.1.3. Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1. and 1.1.2.
and use a Portable Appliance Tester.
1.1.4. Ensure that cables are always protected against short circuit and overload.
1.1.5. Regularly inspect power supply cables and plugs for wear or damage and check all
connections to ensure that none is loose.
1.1.6. Important: Ensure that the voltage marked on the appliance matches the power supply
to be used and that the plug is fitted with the correct fuse - see fuse rating at right.
1.1.7. DO NOT pull or carry the appliance by the power cable.
1.1.8. DO NOT pull the plug from the socket by the cable.
1.1.9. DO NOT use worn or damaged cables, plugs or connectors. Have any faulty item repaired or
replaced immediately by a qualified electrician. When a BS 1363/A UK 3 pin plug is damaged, cut
the cable just above the plug and dispose of the plug safely.
Fit a new plug according to the following instructions (UK only).
a) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
d) After wiring, check that there are no bare wires, that all wires have been connected
correctly, that the cable outer insulation extends beyond the cable restraint and that the
restraint is tight.
Double insulated products, which are always marked with this symbol
and neutral (blue) wires only.
To rewire, connect the wires as indicated above - DO NOT connect either wire to the earth terminal.
1.1.10. Products which require more than 13amps are supplied without a plug. In this case you must contact a qualified electrician to ensure
that a suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin plug and
socket with your electrician.
1.1.11. If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance
plugged into it will be protected. The cable core section is important and should be at least 1.5mm², but to be absolutely sure that the
capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use
of 2.5mm² section cable. If an extension reel is to be used outdoors, ensure it is marked for outdoor use.
1.2
GENERAL SAFETY
 WARNING! Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this
equipment.
 Familiarise yourself with the application , limitations and potential hazards of the soldering station.
 Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
 Locate soldering station in a suitable working area, keep area clean and tidy and free from unrelated materials.
 Keep the work area clean, uncluttered and ensure there is adequate lighting.
 Keep the soldering iron clean for best and safest performance.
 Ensure there are no flammable or combustible materials near the work area.
 Wear approved safety eye protection (standard spectacles are not adequate).
 Wear appropriate protective clothing.
 Ensure the workpiece is adequately held before operating the soldering iron.
 Always replace the soldering iron in its holder when not in use.
© Jack Sealey Limited
INSTRUCTIONS FOR:
SOLDERING STATION 80w
ST80
MODEL NO:
INDOOR USE
HOT SURFACE
ONLY
Original Language Version
, are fitted with live (brown)
RECOMMENDED
FUSE RATING: 3AMP
ST80 Issue:1 31/03/15

Advertisement

loading

Summary of Contents for Sealey ST80

  • Page 1 Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer.
  • Page 2 Model No: ........
  • Page 3 Temperature Scale Selection 4.8.1. To access the system setting pages, press ▲ and▼ buttons simultaneously for 3 seconds. 4.8.2. To switch between Celsius and Fahrenheit scales: press ‘3’ on page 1.’C-F’ will flash. 4.8.3. Toggle either the ▲ and▼ button to change from C to F and back. 4.8.4. Press button ‘3’ to save the change. Original Language Version © Jack Sealey Limited ST80 Issue:1 31/03/15...
  • Page 4 NOTE: the display will return to the main functions automatically after 10 seconds if no key is pressed. 5. MAINTENANCE DO NOT open the casing; there are no user-servicable parts inside. In case of malfunction, return to your Sealey dealer or Service ...