Pcm Data Length; Pcm Sync Frequency; Pcm Master Output Data Format - Huawei MU509 Series Design Manual

Lga module pcm audio design guide
Hide thumbs Also See for MU509 Series:
Table of Contents

Advertisement

HUAWEI LGA Module PCM Audio Design Guide
Module
MC509 series
MU709 series
ME909u-521

2.2.7 PCM DATA Length

The length of PCM data is 16 bits and cannot be changed.

2.2.8 PCM SYNC Frequency

PCM SYNC frequency can be changed according to different PCM bit clocks.
Sync
8K
16K

2.2.9 PCM Master Output Data Format

The default PCM master output data format is as shown in the following figure.
The data format of short sync offset set is as shown in the following figure. This mode
is rarely used and only used for debugging to check the rising or fall timing.
Issue 04 (2016-12-12)
Falling edge
Support (default)
Support (default)
Support (default)
Bit clock
2.048 MHz
×
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1.024 MHz
512 KHz
×
×
×
×
PCM Interface
Rising edge
Not support
Not support
Not support
256 KHz
4.096 MHz
×
×
×
10