REV23M
Commissioning and quick start
1. Remove controller from its base and open
cover of the battery compartment.
2. Remove the black battery transit tab.
The controller will switch itself on.
3. Close the battery compartment and replace
the controller.
4. Switch on the boiler.
Selecting the operating mode
The operating mode selector enables you
to select 5 different operating modes:
Automatic operation with a maximum of
3 heating periods
Continuously comfort mode
Continuously economy mode
Continuously frost protection mode
24-hour mode with current comfort setpoint
Changing temporarily the current
setpoint temperature
The change is
maintained until
the next switching
° C
point is reached!
1. When pressing the
or
first time, the currently valid setpoint temperature
will be displayed. It can be readjusted in
increments of 0.2 °C (max. +/-4 °C).
2. After 3 seconds, the initial display will
automatically appear again.
Changing temporarily the
temperature setpoint (savings tip)
In operating modes
button can be pressed to make a manual
change from comfort to economy mode,
or vice versa. The change will
automatically be canceled when reaching
the next switching point or when
selecting another operating mode.
Symbole
"Time" menu
"Temperature"
T
menu
"Heating
periods" menu
"Absence"
menu
Battery
change
Remote
operation
Absence
(*) Display only possible if these values are delivered by the boiler.
Functions of the roller selector
CLICK
Escape button
Press the Esc button to return to the menu level previously activated or to
leave the menu level in a number of steps until you reach the initial display
(the settings currently displayed will be accepted).
Setting the time of day and the weekday
CLICK
h
If no button is pressed for 20 seconds, the setting
displayed will be accepted and the initial display will
appear again.
Changing temperatures long-term
button for the
CLICK
° C
and
, this
If no button is pressed for 20 seconds, the setting
displayed will be accepted and the initial display will
appear again.
Siemens SBT / HVAC Products
Burner active
Error message
Automatic
operation
Continuously
comfort mode
Continuously
economy mode
Frost
protection
24-hour mode
Comfort
setpoint
Press:
• You access the menu
level
• You activate the menu
• You save the inputs
• You switch to the next
menu item
• You accept the menu
item
h
° C
° C
° C
Economy
setpoint
Setpoint frost
protection
Setpoint remote
operation
Absence
setpoint
Current weekday
Actual room-
temperature
Workingday group
Actual outside
temperature (*)
Weekend group
Hot water temp.
setpoint (*)
Entire week
Actual boiler
water temp. (*)
Time schedule
Roll:
You go from one menu to the next
+
You change the setting variables
(temperature in increments of
0.2 °C, time in increments of
hours and minutes)
You select predefined functions
1. Press:
You access the menu level;
the clock flashes.
2. Press:
You accept the menu;
the hours flash.
3. Roll:
Set the current hour.
4. Press:
You save the input;
the minutes flash.
5. Roll:
Set the current minute.
6. Press:
You save the input;
the weekday flashes.
7. Roll:
Select the current weekday.
8. Press the Esc button to return to the menu level:
the T menu flashes
(change not necessarily required; press
the Esc button again to return to the
initial display).
1. Press: You access the menu level;
the clock flashes.
2. Roll: Toward the display to the T menu.
3. Press: You accept the menu;
symbol
flashes.
4. Press: You accept
;
the setpoint flashes.
5. Roll: Set the comfort temperature
6. Press: You save the input;
symbol
flashes.
7. Press: You accept
; the setpoint flashes.
8. Roll: Set the economy temperature.
9. Press: You save the input;
symbol
flashes.
10. Press: You accept
; the setpoint flashes.
11. Roll: Set the frost protection temperature.
12. Press: You save the input; symbol
flashes.
13. Press: You accept
14. Roll: Set the temperature setpoint
while remote operation is active.
15. Press the Esc button to return to the menu level:
The heating periods
(change not necessarily required; press the
Esc button again to return to the initial display).
CE1B2266en
1 heating
period
2 heating
period
3 heating
period
; the setpoint flashes.