fig 14
4.4 Remove the two screws (fig 14a)
from the cross slide screw retainer.
Retain them for future use.
fig 17
4.7 Install the digital display and one of
the small set screws provided (fig 17a).
Ensure the set screw fits into the slot in
the feed screw.
Install the retaining screws provided - do
not overtighten.
fig 20
4.10 Rotate the handle anticlockwise to
draw the feed nut along the feed screw
until the screw holes in the nut are
aligned with those in the slide. Now
install the screws (taken from the original
nut) that retain the feed nut.
© Jack Sealey Limited
fig 15
a
4.5 Remove the cross slide screw
retainer together with the cross slide
feed screw.
fig 18
a
a
4.8 Install the spacer washer provided
(fig 18a) and the cross slide rest feed
handle.
Original Language Version
fig 16
4.6 Install the new cross feed slide
screw and retainer. Install the two
screws taken from the original retainer.
fig 19
a
4.9 Fit the new cross slide feed nut (fig
19a) on the cross slide feed screw.
The screw holes in the nut must be
facing upwards.