<Adjustment specification>
Adjustment mode
SIM
Display
array
SPF image lead
SIM
SIDE1 1 step:
edge position
50-6
(1st print surface)
c. Rear edge void adjustment (SIM50-1, SIM50-19)
1) Set a scale as shown in the figure below.
2) Set the document size to A4 (8.5" x 11"), and make a copy at 100%.
3) If necessary, perform the following adjustment procedure.
Void amount (Standard value: 4mm or less)
Scale image
4) Execute SIM50-01 and select "DEN-B" with the arrow keys.
The currently set adjustment value is displayed.
5) Enter the set value and press the start key. The correction value is
stored and a copy is made.
<Adjustment specification>
Mode
SIM
Display
text array
Rear edge void
SIM
DEN-B
50-1
Set value Spec value
text
Lead edge
0.1mm
void:
shift
1 - 4mm
Image loss:
3mm or
less
A4(8.5" x 11")
Paper rear edge
Paper rear edge
Set value
Specifi-
cation
1 step:
4mm or
0.1mm shift
less
MX-M182 ADJUSTMENT 6-4
d. Paper off center adjustment (SIM50-10)
Set
1) Set a test chart (UKOG-0089CSZZ) on the document table.
range
2) Select a paper feed port and make a copy. Compare the copy and
the test chart. If necessary, perform the following adjustment
1 - 99
procedure.
3) Execute SIM 50-10. After completion of warm-up, shading is
performed and the currently set off center adjustment value of each
paper feed port is displayed.
Sim50-10 PRT. CENTER
1:TRAY1
2:TRAY2
3:TRAY3
1/2
[
4) Enter the set value and press the start key. The correction value is
stored and a copy is made.
<Adjustment specification>
Adjustment
mod
Tray1
Tray2
Tray3
Tray4
Manual paper
feed tray
Duplex
(Second print
surface)
e. Side edge void area adjustment (SIM26-43)
Note:Before performing this adjustment, be sure to check that the paper
off center adjustment (SIM 50-10) is completed.
1) Set a test chart (UKOG-0089CSZZ) on the document table.
2) Select a paper feed port and make a copy. Compare the copy and
the test chart. If necessary, perform the following adjustment
procedure.
3) Execute SIM 26-43 and set the density mode to SIDE VOID (L),
SIDE VOID (R).
The currently set adjustment value is displayed.
Set
range
1 - 99
4) Enter the set value and press the start key. The correction value is
stored.
<Adjustment specification>
Adjustment
mode
Side void (left)
Side void (right)
Sim50-10 PRT. CENTER
4:TRAY4
50
5:BYPASS
50
6:DUPLEX
50
1- 99]
50
2/2
[
SIM
Display
Set value
text array
SIM
TRAY1
Add 1:
50-10
0.1mm shift
TRAY2
to R side.
TRAY3
TRAY4
Reduce 1:
BYPASS
0.1mm shift
to L side.
DUPLEX
Sim26-43 SIDE VOID
1:SIDE VOID(L)
3
2:SIDE VOID(R)
3
[
0- 10]
3
SIM
Display
Set value
text array
26-43
SIDE
1 step:
VOID (L)
0.5mm shift
SIDE
VOID (R)
50
50
50
1- 99]
50
Specifi-
Set
cation
range
Single:
1 - 99
Center
±2.0mm
Specifi-
Set
cation
range
0.5 - 4mm
1 - 99

Advertisement

loading

This manual is also suitable for:

Mx-m182dMx-m202dMx-m232d