Download Print this page
Sealey VS4022.V2 Instructions Manual

Sealey VS4022.V2 Instructions Manual

Vacuum tester and brake bleeding kit

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
refer to
Wear Protective
instruction
Gloves
manual
1. SAFETY
Keep this product in good working order and condition, take immediate action to repair or replace damaged parts.
9
use approved parts only. unapproved parts will invalidate the warranty.
9
Keep children and unauthorised persons away from the work area.
9
Keep work area clean and tidy and free from unrelated materials.
9
ensure the work area has adequate lighting.
9
DO NOT use the kit to perform a task for which it is not designed.
8
DO NOT hold pump inlet against the skin whilst using the pump.
8
DO NOT allow untrained persons to use the kit.
8
DO NOT use whilst under the influence of drugs, alcohol or intoxicating medication.
8
After use, clean equipment and store in a cool, dry, childproof area.
9
WARNING! Brake fluid will damage paintwork. Any spillage should be flushed with water immediately.
WARNING! Brake fluid is flammable - keep away from sources of ignition, including hot surfaces e.g. exhaust manifold.
dispose of waste liquids in accordance with local authority regulations.
9
WARNING! DO NOT pollute the environment by allowing uncontrolled discharge of fluids.
Always read and comply with the warnings on the brake fluid container.
9
Wear eye protection and keep skin contact to a minimum. If brake fluid enters eyes rinse with plenty of water and seek medical advice.
9
if swallowed seek medical advice immediately.
2. INTRODUCTION
the vacuum tester and brake bleeding kit is a multi-function diagnostic tool with robust compact design. Used to test and diagnose a variety of
essential engine and associated functions including fuel, ignition, transmission and emissions. Kit also includes reservoir, hoses and adaptors for
bleeding brake and clutch systems on cars, commercials and motorcycles. Supplied in a carry-case.
3. SpECIFICATION
model............................Vs4022.V2
contents ........................Vacuum Pump, Fluid Container, Transfer Cap, Vacuum Hoses, Assorted Vacuum Hose Fittings (x8)
4. CONTENTS
item
PArt no.
1
Vs4022.01
2
Vs4022.02
3
Vs4022.03
4
Vs4022.04
5
Vs4022.05
6
Vs4022.06
7
Vs4022.07
© Jack sealey limited
instructions for
VACUUM TESTER AND BRAKE BLEEDING KIT
model no:
Wear eye
Wear Protective
Protection
clothing
descriPtion
VAcuum PumP WitH GAuGe
FLUID HOSE (LONG)
uniVersAl cuP AdAPtor
POT LID (FOR TRANSPORT)
POT LID (FOR OPERATION)
fluid contAiner
VACUUM HOSE (SHORT)
Original Language Version
VS4022.V2
Warning:
Flammable
item
PArt no.
8
VS4022.08
9
Vs4022.09
10
Vs4022.10
11
Vs4022.11
12
Vs4022.12
13
Vs4022.13
14
Vs4022.14
descriPtion
Hose connector "t"
strAiGHt Hose connector
BrAKe Bleed Hose AdAPtor "A"
BrAKe Bleed Hose AdAPtor "B"
BrAKe Bleed Hose AdAPtor "c"
Hose AdAPtor
Hose AdAPtor
VS4022.V2
Issue 1 17/01/18

Advertisement

loading

Summary of Contents for Sealey VS4022.V2

  • Page 1 VS4022.V2 model no: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2: Operation

    Step 3. Start and run the engine at idle, observing the gauge reading. 5.2.3. Refer to the following diagrams (1 to 9) to indicate any problems and their possible causes. © Jack sealey limited Original Language Version VS4022.V2 Issue 1 17/01/18...
  • Page 3 RPM is increased a vacuum increase should be observed. If this does not occur, trace the vacuum line back checking for restrictions and breaks. VS4022.V2 Issue 1 17/01/18 Original Language Version © Jack sealey limited...
  • Page 4 ‘off’ position until a given temperature is reached. © Jack sealey limited Original Language Version VS4022.V2...
  • Page 5 (fig.12). Start and run the engine and apply vacuum pressures. Monitor readings and confirm that these are in conformance with manufacturer’s specifications. fig.7 fig.8 fig.10 fig.9 fig.11 fig.12 © Jack sealey limited Original Language Version VS4022.V2 Issue 1 17/01/18...
  • Page 6 Important: No Liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business park, Bury St Edmunds, Suffolk. Ip32 7AR 01284 757500 01284 703534 sales@sealey.co.uk...