De-icer control
Water level
adjustment
control
switch
Normal fill
Screw
MaxirAm
fill
Do not operate
dehumidifier
at tempera-
tures below 18.3% (65°F). The coils may
become
iced over and unit will not operate
properly.
Your Whirlpool dehumidifier
is equipped with a
feature to help you get the most comfort from
your new appliance by permitting it to operate
down to 18.3% (65°F). If your dehumidifier
runs
when room temperature
and humidity conditions
are low, frost can form on its evaporator coil. This
interferes with proper operation.
The De-icer Control senses frost build-up on
the evaporator coil and automatically
shuts off
the compressor.
The fan continues to run,
drawing air across the coil and melting the frost.
When the coil is defrosted, the compressor
is
automatically
restarted, and dehumidifying
is
resumed.
Setting the water level
adjustment
The Water Level Adjustment can be set in two
positions to turn off the unit automatically
when
the pan is full. This prevents the danger of
overflow.
Pan must be in proper position for Water Level
Control Switch to work.
l
NORMAL
FILL-set
Water Level Adjustment to
the indentation on the left side. The water pan
and water will weigh approximately
7.2 kg (16
Ibs.) and water pan will be l/2 full.
l
MAXIMUM
FILL-set
Water Level Adjustment
to the raised
area
on the
right
side. The water
pan and water will weigh approximately
10.8 kg
(24 Ibs.) and water pan will be 3/4 full.
The Water Level Control Switch will automatically
turn off the dehumidifier
at the fill level you
selected when pan is properly placed. Loosen
the screw to move the Water Level Adjustment.
Retighten screw when adjusted to desired
setting.