13255
13255-91032/03
Cartrldge Tape Module
Fev
AUG-Ol-76
Table 2.0
Peliabil1ty and Environmental Information
=====::==========================================================================
I:.nvlronmentaJ.:
( X ) HP CldSS B
(
) Other:
Restrictions:
Type tested at product level except the cartridge
tape.
The cartridge tape limits temperature and
humidity conditions as follows.
Free space ambient temperature:
Non-operating:
-10
to
+ 65
degrees
C
(-15 to
+150
degrees F)
Operating:
+ 5
to
+
40
degrees
C
(+41
to
+104
degrees
F')
Humidity:
20 to 80% (non-condensing)
====::=========================================================================
Failure Rate (percent per
1000
hours) of Major Assemblies:
CTU Interface PCA
Read/Write peA
CTU Top Plane Assembly
Motor Cable Assembly
CTU Transport Assembly
0.82340%
4.04199%
0.000R8%
0.00060%
4.17800%
Lite expectancy tor components of the CTU Transport Assembly (the maximum
insertion rate
=
1
per second.
Data for the head, motor, and motor
capstan apply to start-stop motion at
10
inches per second):
E.ject, Insert Mechanism
20,000
insertions min.
(50,000
typical)
cartridge Insert and
100,000
insertions min.
file Protect Switches
Head/Write Head
3,000
hours min.
(10,000
hours typical)
14otor
1,000
hours min.
(
5,000
hours typical)
I~Otor
Capstan
1,000
hours min.
(
5,000
hours typical)
=====::==========================================================================

Advertisement