Beko CLEARPOINT 3eco S040 Installation And Operation Manual

Beko CLEARPOINT 3eco S040 Installation And Operation Manual

Coalescing filter

Advertisement

Installation and operation manual
CLEARPOINT
®
> S040
> S075
> S050
> M010
> S055
> M012
08-308
3eco
coalescing filter
> M015
> M018
> M020
> M022
> M023
> M025
> M027
> M030
> M032
en

Advertisement

Table of Contents
loading

Summary of Contents for Beko CLEARPOINT 3eco S040

  • Page 1 Installation and operation manual CLEARPOINT 3eco coalescing filter ® > S040 > S075 > M015 > M025 > S050 > M010 > M018 > M027 > S055 > M012 > M020 > M030 > M022 > M032 > M023 08-308...
  • Page 2: Table Of Contents

    CLEARPOINT ® 3eco coalescing filter Installation and operation manual Content 1. General .............................4 1.1 Contact ................................4 1.2 Information regarding installation and operation manual ..............4 1.3 Other applicable documents ........................4 1.4 Explanation of the symbols and pictograms utilised ................5 1.4.1 In the documentation ........................
  • Page 3 Installation and operation manual CLEARPOINT 3eco coalescing filter ® 9.6 Leakage test ..............................39 10. Shut down ........................... 40 11. Disassembly ..........................41 11.1 Warning ...............................41 11.2 Disassembly work .............................42 12. Disposal ............................44 12.1 Warning ...............................44 12.2 Disposal work ............................44 13.
  • Page 4: General

    Installation and operation manual 1. General 1.1 Contact Manufacturer Customer service and tools BEKO TECHNOLOGIES GmbH BEKO TECHNOLOGIES GmbH Im Taubental 7 | D-41468 Neuss Im Taubental 7 | D-41468 Neuss Tel. + 49 2131 988 - 1000 Tel. + 49 2131 988 - 1000 info@beko-technologies.com...
  • Page 5: Explanation Of The Symbols And Pictograms Utilised

    Installation and operation manual CLEARPOINT 3eco coalescing filter ® 1.4 Explanation of the symbols and pictograms utilised The symbols and pictograms utilised below indicate safety-relevant and important information which must be adhered to when handling the operating material and to ensure safe and optimum operation. 1.4.1 In the documentation Symbol/Pictogram Description/Explanation...
  • Page 6: On The Device

    Filter element sticker CLEARPOINT This sticker is located on the base of the filter element and provides information about the  Flow filter element and the direction of flow. 04FX (04F,04G) Made in Germany label: Products with this sticker have special added value in the form of energy saving and are allocated to the line of BEKO TECHNOLOGIES GMBH products. 6 | 56...
  • Page 7: Intended Use

    • Only use filters and accessories within a pipeline system designed for the technical data with appropriate  connections, pipe diameters and assembly clearance. • Only use the filters and accessories for the treatment of compressed gases of fluid group 2 according to Pressure  Equipment Directive 2014/68/EU which are free of aggressive and corrosive components. • Only use filters and accessories in non-explosive hazardous areas. • Only use filters and accessories away from direct solar radiation and heat sources as well as areas subject to frost. • Only combine the filters and accessories with the products named and recommended by  BEKO TECHNOLOGIES GMBH in the manual. Before using the filters, the operating company must make sure that all conditions and prerequisites for intended use are  given. The filter is exclusively designed for stationary use in a commercial or industrial area. All the assembly, installation,  operation, disassembly and disposal work described may only be performed by qualified skilled personnel. 7 | 56...
  • Page 8: Resonably Foreseeable Inappropriate Use

    CLEARPOINT ® 3eco coalescing filter Installation and operation manual 1.6 Resonably foreseeable inappropriate use Reasonably foreseeable inappropriate use is deemed to have occurred if the filter or any accessories are used in any  other way than that described in the chapter "Intended use". Reasonably foreseeable inappropriate use includes the use of the product in a manner not intended by the manufacturer or supplier but which may result from foreseeable human behaviour.
  • Page 9: Target Group And Personnel

    Installation and operation manual CLEARPOINT 3eco coalescing filter ® 1.8 Target group and personnel This manual addresses the specialist personnel listed below who are involved with work on the filter or the accessories. INFORMATION Personnel requirements The personnel may not execute any actions on the filter or the accessories when they are  under the influence of drugs, medications, alcohol or other substances that may impair their  consciousness. Skilled personnel- Transport and storage Skilled personnel - Transport and storage are people who, due to their training, professional experience and qualifications, have all the necessary skills to safely execute all actions in connection with the transport and storage of ...
  • Page 10: Safety-Related Information

    CLEARPOINT ® 3eco coalescing filter Installation and operation manual 2. Safety-related information 2.1 General instructions Safety instructions warn against residual risks when handling the product. Warning notices in the instructional text precede the procedure that poses a hazard to personnel or the environment. These safety and warning notices must be strictly observed in order to prevent accidents, personal injury, damage to ...
  • Page 11: Safety Instructions

    Installation and operation manual CLEARPOINT 3eco coalescing filter ® 2.2 Safety instructions In order to prevent accidents, personal injury and damage to the device as well as impairments during operation, it is  essential to adhere to the specified safety and warning notices. The personal protective equipment specified in the safety instructions must be selected and made available by the  operating company depending on the system parameters and properties. DANGER Operation of plant outside the permissible limit range! Operation of the product outside the permissible limits and operating parameters, unauthorised intervention and modifications may result in death or serious injury.
  • Page 12: Transport And Storage

    CLEARPOINT ® 3eco coalescing filter Installation and operation manual 3. Transport and storage WARNING Insufficient qualification! Insufficient qualification of the personnel can lead to accidents, personal injury and damage to  the device as well as impairments during work on the operating material. The work on the operating material described below must only be executed by specialist personnel during transport and storage.
  • Page 13: Product Information

    Safety slide with locking screw label: Products with this sticker have special added value in the form of energy saving and are allocated to the line of BEKO TECHNOLOGIES GMBH products. Type plate Filter housing with internal sealing ring Maintenance sticker for filter element replacement...
  • Page 14: Product Identification

    CLEARPOINT ® 3eco coalescing filter Installation and operation manual 4.3 Product identification The product designation is shown on the type plate and made up of numbers and letter codes. Each code stands for a filter component and is divided into the following categories: [1] = Size: Housing [2] = Filter elements [3] = Attachment components top [4] = Attachment components bottom The product designation is explained below using the example “S040CWF”:...
  • Page 15 Installation and operation manual CLEARPOINT 3eco coalescing filter ® Attachment components top Position no. Letter code Designation Differential pressure gauge with potential-free contact Differential pressure gauge without potential-free contact Without indicator unit Filter elements Position no. Letter code Designation 99.9% separation Residual oil Compressed air rate solid particles content class in acc. with [μm] [mg/m³] (ISO 8573 - 1)
  • Page 16: Function Description

    CLEARPOINT ® 3eco coalescing filter Installation and operation manual 4.4 Function description 4.4.1 Filtration With the CLEARPOINT 3eco coalescing filter, the medium flows through the filter element from the inside to the  ® outside. Compressed gas flows into the filter element from where it flows through the filter element into the filter vessel.  During this process, particles as well as oil and water aerosols are separated by the filter material. The liquid components  in the filter material move downwards due to gravity, drip off and collect at the base of the filter vessel. From there, they  are drained off automatically or manually. Over time, particles become deposited in the filter material. This results in an  increase in flow resistance (differential pressure) of the filter element. The particle charge or degree of pollution of the filter element can be read off using a differential pressure gauge. More  detailed information about this can be found in the installation and operation manual enclosed with the differential  pressure gauge. 16 | 56...
  • Page 17: Condensate Discharge Through Float Drain

    Installation and operation manual CLEARPOINT 3eco coalescing filter ® 4.4.2 Condensate discharge through float drain Float drains are mechanical condensate drains that work automatically as they are closed and opened based on the buoyancy of a float body [1]. When the condensate [2] in the vessel rises to a certain level, buoyant force pushes the float body [1] up and opens the outlet channel [3] for the condensate. The float body closes again when the condensate ...
  • Page 18: Condensate Discharge Through Bekomat

    CLEARPOINT ® 3eco coalescing filter Installation and operation manual 4.4.3 Condensate discharge through BEKOMAT Condensate discharge can also take place via the automatic BEKOMAT condensate discharge. ® More detailed information can be found in the installation and operation manual for the BEKOMAT ®...
  • Page 19: Type Plate

    Volume: Test pressure PT: 23 bar / 334 psi Connection: pipe G 1/2 drain G 1/2 Fluidgroup 2 PED2014/68/EU / Cat. - BEKO TECHNOLOGIES GmbH beko-technologies.com Made in Germany Example: Position on rating plate Description Super Fine Filter BEKO filter designation Model: Sales designation Material no.
  • Page 20: Filter Element Sticker

    CLEARPOINT ® 3eco coalescing filter Installation and operation manual 4.7 Filter element sticker The filter element can be identified on the basis of a sticker on the base of the filter element.  There are different filter elements for different applications and degrees of filtration. 4038104 W5822635/002 CLEARPOINT Flow 04FX (04F,04G) Made in Germany Sticker on the base of the filter element Filter element sticker View filter element base Position no. Explanation/description Order number Lot number Product group Direction of flow 04FX designation of the filter element 04F, 04G designation of predecessor filter element in brackets 4.8 Maintenance sticker for filter element replacement The next due filter element replacement date is entered on this sticker. For this, mark the respective month [1] and enter...
  • Page 21: Technical Data

    Installation and operation manual CLEARPOINT 3eco coalescing filter ® 5. Technical data 5.1 Filter performance data CLEARPOINT 3eco S040 S050 S055 S075 M010 M012 M015 ® Connection [inches] 1 1/2 Volume flow at 7 bar(g)  energy-optimised [m³/h] Ø 50 Differential  pressure [mbar] (wet saturated) Volume flow at 7 bar(g) ...
  • Page 22: Filter Element Performance Data

    CLEARPOINT ® 3eco coalescing filter Installation and operation manual CLEARPOINT 3eco M018 M020 M022 M023 M025 M027 M030 M032 ® Connection [inches] 1 1/2 2 1/2 2 1/2 Volume flow at 7 bar(g)  1020 1300 1620 1940 2400 energy-optimised [m³/h] Ø 50 Differential  pressure [mbar] (wet saturated) Volume flow at 7 bar(g) ...
  • Page 23: Materials

    Installation and operation manual CLEARPOINT 3eco coalescing filter ® 5.3 Materials Component Material S040 ... M012: Aluminium (die-cast), anodised, powder-coated Housing head (filter head) M015 ... M032: Aluminium (sand-cast), anodised, powder-coated Housing body S040 ... M032: Aluminium (extruded profile), anodised, powder-coated Housing cover Polyamide PA6, 30 % glass fibre reinforced  S040 ... M012: Aluminium (die-cast), anodised, powder-coated Housing base M015 ...
  • Page 24: Dimensions

    CLEARPOINT ® 3eco coalescing filter Installation and operation manual 6. Dimensions 24 | 56...
  • Page 25 Installation and operation manual CLEARPOINT 3eco coalescing filter ® Connection Filter Filter thread element G / NPT [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [inches] S040 (type) 64.5 39.5 04 (type) S050 (type) 64.5 39.5 05 (type) S055 (type) 64.5 39.5...
  • Page 26: Assembly

    CLEARPOINT ® 3eco coalescing filter Installation and operation manual 7. Assembly 7.1 Warning DANGER Use of incorrect spare parts, accessories or installation materials! The use of incorrect spare parts, accessories or installation materials, as well as auxiliary and operating materials, may result in death or serious injury. In addition, functional and operational  malfunctions or material damage can occur. •...
  • Page 27: Assembly Work

    Installation and operation manual CLEARPOINT 3eco coalescing filter ® 7.2 Assembly work For assembly work to be carried out, the following prerequisites must be fulfilled and the preparatory tasks must have  been completed. Prerequisites Tools Material Protective equipment • Screwdriver - cross-head size 2.5 • Additional installation and • Protective gloves (fluid- operating manual for the resistant) accessories used • Safety goggles with side shields •...
  • Page 28 CLEARPOINT ® 3eco coalescing filter Installation and operation manual The direction of flow of the filter must be taken into account during assembly. It must be adapted to the direction of flow  in the pipe. Direction of flow Direction of flow Left » right (default) Right » Left The housing head and the housing body are equipped with a double-start trapezoidal thread. The direction of flow of  the filter can be adapted to the direction in the pipe by turning the housing head through 180°. The direction of flow is  indicated by arrows [2] and a raised marking [3] on the housing head. These must be aligned as shown. The safety slide [1] must always be in an easily accessible position on the front.
  • Page 29: Commissioning

    Installation and operation manual CLEARPOINT 3eco coalescing filter ® 8. Commissioning 8.1 Commissioning tasks For commissioning to be carried out, the following prerequisites must be fulfilled and the preparatory tasks must have  been completed. Prerequisites Tools Material Protective equipment • none • none • None Preparation of installation Assembly finished including subsequent leakage test Figure Description Automatic discharge Mechanically open 1. Set the knurled screw on the float  drain from >>Mechanically open<<...
  • Page 30: Maintenance And Servicing

    CLEARPOINT ® 3eco coalescing filter Installation and operation manual 9. Maintenance and servicing 9.1 Maintenance schedule Maintenance Interval At regular intervals, depending on the degree of Cleaning work contamination Visual inspection Weekly Replace the float drain Annually Replace the filter element Annually or with a differential pressure ≥ 0.4 bar Recommended interval: At the end of all assembly work Leakage test and maintenance and servicing work on the product 9.2 Cleaning...
  • Page 31: Cleaning Work

    Installation and operation manual CLEARPOINT 3eco coalescing filter ® 9.2.2 Cleaning work For cleaning to be carried out, the following prerequisites must be fulfilled and the preparatory tasks must have been  completed. Prerequisites Tools Material Protective equipment • None • Mild detergent • Protective gloves (fluid- • Cotton cloth or disposable tissue resistant) • Safety goggles with side shields • Hearing protection •...
  • Page 32: Replace The Float Drain

    CLEARPOINT ® 3eco coalescing filter Installation and operation manual 9.4 Replace the float drain For float drain replacement to be carried out, the following prerequisites must be fulfilled and the preparatory tasks  must have been completed. Prerequisites Tools Material Protective equipment • Screwdriver - cross-head • New float drain with adapter  • Protective gloves (fluid- size 2.5 mm enclosed resistant) • Safety goggles with side shields •...
  • Page 33 Installation and operation manual CLEARPOINT 3eco coalescing filter ® 3. Undo the locking screw on the safety slide 4. Push the safety slide downwards 5. Unscrew the housing body 6.  Pull the housing body down and off To screw the float drain out, use the size 13 adapter  enclosed with the float drain. 7.  Use the adapter to screw the float drain out anti- clockwise 8.  Lift the float drain out of the top of the housing body 33 | 56...
  • Page 34 CLEARPOINT ® 3eco coalescing filter Installation and operation manual 9.  Dispose of the float drain properly and in line with the  regional requirements. For more information, see “12. Disposal” on Page 44. 10. Insert a new float drain into the housing body 11. Screw the float drain into the housing body clockwise  by hand 12. Tighten the float drain using the adapter 34 | 56...
  • Page 35 Installation and operation manual CLEARPOINT 3eco coalescing filter ® 13. Screw the housing body back onto the filter head Make sure that the safety slide is facing the front after assembly. 14. Push the safety slide upwards 15. Tighten the locking screw on the safety slide 16. Slowly open the shut-off valves upstream and  downstream of the filter or the respective system  section 17.
  • Page 36: Replace The Filter Element

    CLEARPOINT ® 3eco coalescing filter Installation and operation manual 9.5 Replace the filter element For filter element replacement to be carried out, the following prerequisites must be fulfilled and the preparatory tasks  must have been completed. Prerequisites Tools Material Protective equipment • Screwdriver - cross-head • New filter element • Protective gloves (fluid- size 2.5 mm resistant) • Safety goggles with side shields •...
  • Page 37 Installation and operation manual CLEARPOINT 3eco coalescing filter ® 3. Undo the locking screw on the safety slide 4. Push the safety slide downwards 5. Unscrew the housing body 6.  Pull the housing body down and off 7.  Pull the used filter element down and out of the  housing head 37 | 56...
  • Page 38 CLEARPOINT ® 3eco coalescing filter Installation and operation manual 8.  Insert a new filter element in the housing head The direction of flow indicated on the housing head  and the filter element base must match Flow 9. Screw the housing body to the housing head Make sure that the safety slide is facing the front. 10. Push the safety slide upwards 11. Tighten the locking screw on the safety slide 38 | 56...
  • Page 39: Leakage Test

    9.6 Leakage test The leakage test is a non-destructive test method and is used to prove leak tightness in vacuum and overpressure systems. The leakage test can be carried out in different ways. BEKO TECHNOLOGIES GMBH does not make a specific recommendation here. The company operating the compressed gas system is responsible for the selection  and specification of the test method to be used, which should be carried out in accordance with valid standards and  regulations (e.g. DIN EN 1779). 39 | 56...
  • Page 40: Shut Down

    CLEARPOINT ® 3eco coalescing filter Installation and operation manual 10. Shut down Figure Description 1. Open the shut-off valve [3] of the bypass pipe (if available) 2. Close the shut-off valve [2] on the outlet side 3. Close the shut-off valve [1] on the inlet side Figure Description Automatic discharge Mechanically open 4.
  • Page 41: Disassembly

    Installation and operation manual CLEARPOINT 3eco coalescing filter ® 11. Disassembly 11.1 Warning DANGER Use of incorrect accessories, materials or spare parts! The use of incorrect spare parts, accessories or installation materials, as well as auxiliary and operating materials, may result in death or serious injury. In addition, functional and operational  malfunctions or material damage can occur. •...
  • Page 42: Disassembly Work

    CLEARPOINT ® 3eco coalescing filter Installation and operation manual 11.2 Disassembly work For disassembly to be carried out, the following prerequisites must be fulfilled and the preparatory tasks must have been  completed. Prerequisites Tools Material Protective equipment • Screwdriver - cross-head • none • Protective gloves (fluid- size 2.5 mm resistant) • Safety goggles with side shields • Hearing protection •...
  • Page 43 Installation and operation manual CLEARPOINT 3eco coalescing filter ® 3. Undo the locking screw on the safety slide 4. Push the safety slide downwards 5. Unscrew the housing body 6.  Pull the housing body down and off 7.   Remove the filter element 8. Remove the filter head from the pipe and seal the ends of the pipe properly 9. Dispose of the component properly 43 | 56...
  • Page 44: Disposal

    CLEARPOINT ® 3eco coalescing filter Installation and operation manual 12. Disposal 12.1 Warning DANGER Use of incorrect accessories, materials or spare parts! The use of incorrect spare parts, accessories or installation materials, as well as auxiliary and operating materials, may result in death or serious injury. In addition, functional and operational  malfunctions or material damage can occur. •...
  • Page 45: Spare Parts And Accessories

    Installation and operation manual CLEARPOINT 3eco coalescing filter ® 13. Spare parts and accessories 13.1 Spare parts Designation Figure Separate documentation O-ring set for S040, S050, S055  4026562 O-ring set for S075, M010, M012  4026563  Enclosed instruction leaflet O-ring set for M015, M018, M020, M022, M023 ...
  • Page 46: Accessories Attachment Components Bottom

    CLEARPOINT ® 3eco coalescing filter Installation and operation manual 13.3 Accessories attachment components bottom Designation Figure Separate documentation Float drain (opened when pressureless)  4025536  Enclosed instruction leaflet Float drain (closed when pressureless)  4025537 BEKOMAT Enclosed installation and ®  4001841 operation manual BEKOMAT 20 FM...
  • Page 47: Troubleshooting / Faq

    Installation and operation manual CLEARPOINT 3eco coalescing filter ® 14. Troubleshooting / FAQ Error or fault pattern Possible causes Remedy • Change operating method • Avoid pressure surges Excessive load, load surges • Observe the prescribed operating parameters, particularly during start-up processes Non-functioning condensate •...
  • Page 48: Product Approvals And Registration Marks

    CLEARPOINT ® 3eco coalescing filter Installation and operation manual 15. Product approvals and registration marks Symbol/Pictogram Description/Explanation CE marking on the filter Applicable for sizes M020, M022, M025, M027, M030 und M032 48 | 56...
  • Page 49 Installation and operation manual CLEARPOINT 3eco coalescing filter ® 49 | 56...
  • Page 50 CLEARPOINT ® 3eco coalescing filter Installation and operation manual BEKO TECHNOLOGIES GMBH Im Taubental 7 41468 Neuss GERMANY Tel: +49 2131 988-0 www.beko-technologies.com Herstellererklärung Wir erklären hiermit, dass die nachfolgend bezeichneten Produkte, in den von uns gelieferten Ausführungen gemäß Druckgeräterichtlinie 2014/68/EU Artikel 4 Absatz 3 in Übereinstimmung mit der geltenden guten Ingenieurpraxis ausgelegt und hergestellt werden.
  • Page 51 Installation and operation manual CLEARPOINT 3eco coalescing filter ® BEKO TECHNOLOGIES GMBH Im Taubental 7 41468 Neuss GERMANY Phone: +49 2131 988-0 www.beko-technologies.com Manufacturer Declaration We hereby declare that the products indicated hereafter, in the condition in which they have been placed into circulation, have been designed and manufactured according to sound engineering practice, in compliance with Article 4, Paragraph 3 of the European Pressure Equipment Directive 2014/68/EC.
  • Page 52 CLEARPOINT ® 3eco coalescing filter Installation and operation manual BEKO TECHNOLOGIES GMBH Im Taubental 7 41468 Neuss GERMANY Tel: +49 2131 988-0 www.beko-technologies.com EU-Konformitätserklärung Wir erklären hiermit, dass die nachfolgend bezeichneten Produkte den Anforderungen der einschlägigen Richtlinien und technischen Normen entsprechen. Diese Erklärung bezieht sich nur auf die Produkte in dem Zustand, in dem sie von uns in Verkehr gebracht wurden.
  • Page 53 Installation and operation manual CLEARPOINT 3eco coalescing filter ® BEKO TECHNOLOGIES GMBH Im Taubental 7 41468 Neuss GERMANY Phone: +49 2131 988-0 www.beko-technologies.com EU Declaration of Conformity We hereby declare that the products named below comply with the stipulations of the relevant directives and technical standards.
  • Page 54 CLEARPOINT ® 3eco coalescing filter Installation and operation manual 54 | 56...
  • Page 55 The products bear the CE Mark: 0045 The manufacturer shall have sole responsibility for issuing this declaration of conformity. Signed for and on behalf of: Neuss, 01/09/2017 BEKO TECHNOLOGIES GMBH i.V. Christian Riedel Head of International Quality Management EU-decl_CP_M025-M032_FL2_Kat.II_en_09_2017.docx 55 | 56...
  • Page 56 Tel. +86 21 508 158 85 info.cn@beko-technologies.cn BEKO Tecnológica España S.L. BEKO TECHNOLOGIES LIMITED BEKO TECHNOLOGIES INDIA Pvt. Ltd. Torruella i Urpina 37-42, nave 6 Unit 1010 Miramar Tower Plot No.43/1 CIEEP Gandhi Nagar E - 08758 Cervelló 132 Nathan Rd.

Table of Contents