Manual Control; Communications Menu - Bosch MIC SERIES 500 CAMERA 500 User Manual

Bosch appliances security camera user manual
Hide thumbs Also See for MIC SERIES 500 CAMERA 500:
Table of Contents

Advertisement

30
en | Navigating the Menus
5.5.3

Manual Control

The MANUAL CONTROL feature enables the user to manually control the unit for ten (10)
seconds while setting a preset position. A time remaining caption counts down at the top of
the screen. At the end of the countdown, the unit stops in its current position. If more
movement is required, press right on the Manual Control. This allows the user an additional
ten (10) seconds of manual control.
5.6

Communications Menu

The communications page provides the selection of the MIC Address, Protocol and Baud Rate.
Once modified, the settings only take effect once the menu has been exited and the
confirmation page has been accepted. The address field allows values in the range 1 to 254,
this will be carried over between protocols.
The MIC 500 Series Camera provides twin protocol support in one release of software. The
camera's operating protocol can be switched using the Cam-set or the "Protocol" setting in
this menu section. The protocol pack options are: FV/Bosch (default), FV/Pelco and FV/VCL.
Menu Item
Description
ADDRESS
Allows the appropriate camera to be operated via the numerical address in the control system. The
address may be set locally using Cam-set. To change the address using Cam-set, enter the desired
address in the New Address field then, press Configure MIC Communications. The MIC
Communications Settings menu is displayed. Modify the settings then, press Apply (optional 1-254
addresses).
PROTOCOL
Enables the user to switch between the protocols in the loaded protocol pack. Options are: FV/
Bosch (default), FV/Pelco or FV/VCL.
BAUD RATE
Enables the user to toggle between 4800 and 9600 Baud rate. The speed at which
telecommunication data is transmitted, measured in bits per second (Bps).
The "Baud Rate" setting provides a full range of values, 1200, 2400, 4800, 9600, 19200 or
38400 for each protocol. Not all protocol controllers support this full range, so ensure that the
correct option is selected before confirming.
Modifying any of these parameters and then confirming the selection causes immediate loss
of control until the control system is reconfigured to match. If a protocol, address or baud
rate option is made that cannot be obtained through the control system, the camera must be
reset using the Configure MIC Communications function of Cam-set.
Modifying any of these values invokes an extra page to appear when exiting the menu. To
accept the changes made, move the line down to APPLY SETTINGS and press right. To ignore
them, press right on DISCARD SETTINGS.
F.01U.173.601 | 2.0 | 2010.11
MAIN MENU
1/2
MIC SETUPS
ACTIVATE FEATURE
PRESET TOUR
PATTERN TOUR
PRESETS
COMMUNICATIONS
ADVANCED SETUPS
ALARMS
..COMMUNICATIONS..
ADDRESS
1
PROTOCOL
BOSCH
BAUD RATE
-------------------------------------------
: WARNING CHANGING :
: ANY SETTING MAY
: CAUSE A LOSS OF
: CONTROL
User's Manual
MIC Series 500 Camera
:
:
:
Bosch Security Systems, Inc.

Advertisement

Table of Contents
loading

Table of Contents