Mechanical Design-In; Form Factors - Philips Xitanium LED Xtreme SR Design-In Manual

Table of Contents

Advertisement

Mechanical Design-in

LCN9620 SimpleSet interface tool
Design-in Guide - Philips Xitanium LED Xtreme SR driver

Form factors

Xitanium LED Xtreme SR drivers are available in different
housing dimensions. The specific dimensions can be found in
the driver datasheet. 3D CAD files are available to verify fit and
can be found at www.philips.com/technology.
It is recommended to build in drivers such that the driver housing
and the driver input and output connectors are not affected by
potential water ingress in the luminaire (e.g. due to luminaire sealing
malfunction or condensation).
It is highly recommended to mount the driver by using all available
mounting feet in order to achieve maximum mechanical robustness
against shocks and vibration. The recommended mounting torque is
1.5Nm for drivers with plastic mounting feet. This value should not
be exceeded in order to prevent deformation of the mounting feet.
Note: The use of rivets is not recommended since mounting torque
cannot be controlled. Damage to the mounting feet and loose
mounting may result.
Mounting screw dimensions should be based on the specified fixing
hole diameter in the driver datasheet. Oversized and undersized
screws should not be used in order to prevent damage to the
mounting feet or loose mounting.
Allow for sufficient free space around the driver SimpleSet
antenna if the driver is to be configured after mounting in the
luminaire. The minimum recommended space is depending on the
type of SimpleSet configuration tool. Using the tool as shown here
(LCN9620), the minimum distance is 19 mm (+/-1mm).
Depending on the application and the use in development, factory or
field, another configuration tool can be selected. Please check the
website www.philips.com/multione to find
Every published interface tool is officially approved for use with the
MultiOne software. The tool type number can be found by checking
the LCN label on the tool itself.
Note: the use of an unapproved tool may result in impaired driver-
tool communication and configuration malfunctioning.
the correct type.