Parameter Description

3 Parameter Description

3.1 K-## Keypad Set-up

3
3
Parameters related to the fundamental functions of the
frequency converter, function of the keypad buttons and
configuration of the keypad display.
3.1.1 K-0# Keypad Basic Settings
Parameter group for basic frequency converter settings.
K-01 Language
Option:
[0]
English
*
[1]
Deutsch
[2]
Francais
[4]
Spanish
[5]
Italiano
[10] Chinese
[12] Bras.port
[22] English US
[24] Russian
K-02 Motor Speed Unit
Option:
Function:
NOTICE
This parameter cannot be adjusted while the
motor is running.
NOTICE
Changing the motor speed unit resets certain
parameters to their initial value. Select the
motor speed unit before modifying other
parameters.
[0]
RPM Select to show motor speed variables and parameters
using motor speed (RPM).
[1]
Hz
Select to show motor speed variables and parameters
*
using output frequency (Hz).
K-03 Regional Settings
Option:
24
Function:
Defines the language to be used in the display.
The frequency converter is delivered with 9
different languages.
Function:
NOTICE
This parameter cannot be adjusted while
the motor is running.
The display output depends on the settings in
parameter K-02 Motor Speed Unit and
K-03 Regional Settings
Option:
[0]
Interna-
tional
[1]
US
*
K-04 Operating State at Power-up
Option:
[0]
Resume
*
[1]
Forced
stop,
ref=old
K-05 Local Mode Unit
Option:
[0]
As Motor
*
Speed Unit
[1]
%
03/2016 All rights reserved.
Function:
parameter K-03 Regional Settings. The default
settings of parameter K-02 Motor Speed Unit and
parameter K-03 Regional Settings depend on which
region of the world the frequency converter is
supplied to. Reprogram the settings as required.
The settings not used are made invisible.
Sets parameter P-07 Motor Power [kW] units to
[kW] and the default value of parameter F-04 Base
Frequency [50 Hz].
Sets parameter P-02 Motor Power [HP] units to [hp]
and the default value of parameter F-04 Base
Frequency to 60 Hz.
Function:
Select the operating mode after reconnection of
the frequency converter to mains voltage after
power-down when operating in hand-on (local)
mode.
Resumes operation of the frequency converter
maintaining the same local reference and the
same start/stop condition (applied by [Hand]/
[Off] on the keypad or local start via a digital
input as before the frequency converter was
powered down.
Stops the frequency converter, but at the same
time retains the local speed reference before
power-down in the memory. After mains
voltage is reconnected and after receiving a
start command (pressing [Hand] or local start
command via a digital input), the frequency
converter restarts and operates at the retained
speed reference.
Function:
Defines if the local reference unit is shown
in terms of the motor shaft speed (in
RPM/Hz) or as percent.
DET-620D