Mitsubishi Electric M Series Manual page 125

Hide thumbs Also See for M Series:
Table of Contents

Advertisement

M series
COOL operation at Rated frequency
MSZ-GE35VA: MUZ-GE35VA MUZ-GE35VAH
CAPACITY: 3.5 kW
SHF: 0.82
INDOOR
INDOOR
DB (°C)
WB (°C)
Q
SHC
21
18
3.43
2.20
21
20
3.61
1.87
22
18
3.43
2.33
22
20
3.61
2.02
22
22
3.82
1.68
23
18
3.43
2.47
23
20
3.61
2.16
23
22
3.82
1.83
24
18
3.43
2.61
24
20
3.61
2.31
24
22
3.82
1.98
24
24
4.03
1.61
25
18
3.43
2.74
25
20
3.61
2.45
25
22
3.82
2.14
25
24
4.03
1.77
26
18
3.43
2.88
26
20
3.61
2.60
26
22
3.82
2.29
26
24
4.03
1.93
26
26
4.24
1.52
27
18
3.43
3.02
27
20
3.61
2.74
27
22
3.82
2.44
27
24
4.03
2.09
27
26
4.24
1.69
28
18
3.43
3.16
28
20
3.61
2.88
28
22
3.82
2.59
28
24
4.03
2.25
28
26
4.24
1.86
29
18
3.43
3.29
29
20
3.61
3.03
29
22
3.82
2.75
29
24
4.03
2.42
29
26
4.24
2.03
30
18
3.43
3.43
30
20
3.61
3.17
30
22
3.82
2.90
30
24
4.03
2.58
30
26
4.24
2.20
31
18
3.43
3.43
31
20
3.61
3.32
31
22
3.82
3.05
31
24
4.03
2.74
31
26
4.24
2.37
32
18
3.43
3.43
32
20
3.61
3.46
32
22
3.82
3.20
32
24
4.03
2.90
32
26
4.24
2.54
NOTE
Q : Total capacity (kW)
SHC : Sensible heat capacity (kW)
INPUT: 865 W
OUTDOOR DB (°C)
35
40
SHF
INPUT
Q
SHC
0.64
848
3.15
2.02
0.52
882
3.36
1.75
0.68
848
3.15
2.14
0.56
882
3.36
1.88
0.44
917
3.57
1.57
0.72
848
3.15
2.27
0.60
882
3.36
2.02
0.48
917
3.57
1.71
0.76
848
3.15
2.39
0.64
882
3.36
2.15
0.52
917
3.57
1.86
0.40
952
3.78
1.51
0.80
848
3.15
2.52
0.68
882
3.36
2.28
0.56
917
3.57
2.00
0.44
952
3.78
1.66
0.84
848
3.15
2.65
0.72
882
3.36
2.42
0.60
917
3.57
2.14
0.48
952
3.78
1.81
0.36
986
3.99
1.44
0.88
848
3.15
2.77
0.76
882
3.36
2.55
0.64
917
3.57
2.28
0.52
952
3.78
1.97
0.40
986
3.99
1.60
0.92
848
3.15
2.90
0.80
882
3.36
2.69
0.68
917
3.57
2.43
0.56
952
3.78
2.12
0.44
986
3.99
1.76
0.96
848
3.15
3.02
0.84
882
3.36
2.82
0.72
917
3.57
2.57
0.60
952
3.78
2.27
0.48
986
3.99
1.92
1.00
848
3.15
3.15
0.88
882
3.36
2.96
0.76
917
3.57
2.71
0.64
952
3.78
2.42
0.52
986
3.99
2.07
1.00
848
3.15
3.15
0.92
882
3.36
3.09
0.80
917
3.57
2.86
0.68
952
3.78
2.57
0.56
986
3.99
2.23
1.00
848
3.15
3.15
0.96
882
3.36
3.23
0.84
917
3.57
3.00
0.72
952
3.78
2.72
0.60
986
3.99
2.39
SHF : Sensible heat factor
INPUT : Total power input (W)
WALL-MOUNTED Inverter Heat Pump
46
SHF
INPUT
Q
SHC
SHF
0.64
900
2.91
1.86
0.64
0.52
926
3.12
1.62
0.52
0.68
900
2.91
1.98
0.68
0.56
926
3.12
1.74
0.56
0.44
969
3.33
1.46
0.44
0.72
900
2.91
2.09
0.72
0.60
926
3.12
1.87
0.60
0.48
969
3.33
1.60
0.48
0.76
900
2.91
2.21
0.76
0.64
926
3.12
1.99
0.64
0.52
969
3.33
1.73
0.52
0.40
995
3.57
1.43
0.40
0.80
900
2.91
2.32
0.8
0.68
926
3.12
2.12
0.68
0.56
969
3.33
1.86
0.56
0.44
995
3.57
1.57
0.44
0.84
900
2.91
2.44
0.84
0.72
926
3.12
2.24
0.72
0.60
969
3.33
2.00
0.60
0.48
995
3.57
1.71
0.48
0.36
1029
3.75
1.35
0.36
0.88
900
2.91
2.56
0.88
0.76
926
3.12
2.37
0.76
0.64
969
3.33
2.13
0.64
0.52
995
3.57
1.86
0.52
0.40
1029
3.75
1.50
0.40
0.92
900
2.91
2.67
0.92
0.80
926
3.12
2.49
0.80
0.68
969
3.33
2.26
0.68
0.56
995
3.57
2.00
0.56
0.44
1029
3.75
1.65
0.44
0.96
900
2.91
2.79
0.96
0.84
926
3.12
2.62
0.84
0.72
969
3.33
2.39
0.72
0.60
995
3.57
2.14
0.60
0.48
1029
3.75
1.80
0.48
1.00
900
2.91
2.91
1.00
0.88
926
3.12
2.74
0.88
0.76
969
3.33
2.53
0.76
0.64
995
3.57
2.28
0.64
0.52
1029
3.75
1.95
0.52
1.00
900
2.91
2.91
1.00
0.92
926
3.12
2.87
0.92
0.80
969
3.33
2.66
0.80
0.68
995
3.57
2.43
0.68
0.56
1029
3.75
2.10
0.56
1.00
900
2.91
2.91
1.00
0.96
926
3.12
2.99
0.96
0.84
969
3.33
2.79
0.84
0.72
995
3.57
2.57
0.72
0.60
1029
3.75
2.25
0.60
DB : Dry-bulb temperature
WB : Wet-bulb temperature
INPUT
934
977
934
977
1003
934
977
1003
934
977
1003
1038
934
977
1003
1038
934
977
1003
1038
1073
934
977
1003
1038
1073
934
977
1003
1038
1073
934
977
1003
1038
1073
934
977
1003
1038
1073
934
977
1003
1038
1073
934
977
1003
1038
1073
C-123

Hide quick links:

Advertisement

Table of Contents
loading