Mitsubishi Electric M Series Manual page 233

Hide thumbs Also See for M Series:
Table of Contents

Advertisement

M series
(5) Press
button to turn the weekly timer ON. (
•When the weekly timer is ON, the day of the week whose timer setting is complete, will light.
Press
button again to turn the weekly timer OFF. (
NOTE:
The saved settings will not be cleared when the weekly timer is turned OFF.
2. Checking weekly timer setting
(1) Press
button to enter the weekly timer setting mode.
*
blinks.
(2) Press
or
buttons to view the setting of the particular day or number.
(3) Press
button to exit the weekly timer setting.
NOTE:
When all days of the week are selected to view the settings and a different setting is included among them,
displayed.
h. i-save ( ) OPERATION
1. How to set i-save operation
(1) Press OPERATE/STOP (ON/OFF) button.
(2) Select COOL, HEAT or ECONO COOL mode.
(3) Press i-save button.
(4) Set the temperature, fan speed, and airflow direction for i-save operation.
NOTE:
• i-save operation cannot be selected during DRY or AUTO mode operation.
• The setting range of HEAT mode i-save operation is 10°C and 16 - 31°C.
• 2 groups of setting can be saved. (One for COOL/ECONO COOL, one for HEAT)
2. How to cancel operation
• Press i-save button again.
• i-save operation can also be cancelled by pressing OPERATION SELECT button to change the operation mode.
The same setting is select from the next time by simply pressing i-save button.
i. EMERGENCY/TEST OPERATION
In case of test run operation or emergency operation, use
EMERGENCY OPERATION switch on the right side of the indoor
unit. Emergency operation is available when the remote controller is
missing, has failed or the batteries of the remote controller run down.
The unit will start and OPERATION INDICATOR lamp will light.
The first 30 minutes of operation is the test run operation. This
operation is for servicing. The indoor fan runs at High speed and the
system is in continuous operation (The thermostat does not work).
After 30 minutes of test run operation, the system shifts to
EMERGENCY COOL/HEAT MODE with a set temperature of 24°C.
The fan speed shifts to Med.
In the test run or emergency operation, the horizontal vane operates in
VANE AUTO ( ) mode.
Emergency operation continues until EMERGENCY OPERATION
switch is pressed once (or twice) or the unit receives any signal from
the remote controller. In case of latter, normal operation will start.
NOTE: Do not press EMERGENCY OPERATION switch during normal operation.
j. 3-MINUTE TIME DELAY OPERATION
When the system turns OFF, compressor will not restart for 3 minutes as 3-minute time delay function operates to protect
compressor from overload.
lights.)
Emergency
operation switch
(E.O. SW)
WALL-MOUNTED MSZ-SF•VA Series
goes out.)
Operation mode
Set temperature
Fan speed
Horizontal vane
The operation mode is indicated by the
Operation Indicator lamp as following
Operation Indicator lamp
EMERGENCY COOL
EMERGENCY HEAT
STOP
will be
COOL/HEAT
24°C
Med.
Auto
Lighted
Not lighted
C-231