HUAWEI MU736 HSPA+ M.2 Module
Connection Management API
1.7.1 GetHardwareRevision
Description
This function returns the hardware revision of the device.
Function timeout
30 sec
Prototype
ULONG GetHardwareRevision(
BYTE stringSize,
CHAR * pString);
Parameters
Type
BYTE
CHAR *
1.7.2 SetPower
Description
This function sets the operation mode of the device.
Function timeout
30 sec The function returns result in a 1 sec timeout added to 30 sec.
Prototype
ULONG SetPower(ULONG powerMode);
Parameters
Type
ULONG
Issue 01(2013-03-12)
The function returns result in a 1 sec timeout added to 30 sec.
Variable
stringSize
pString
Variable
powerMode
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
HW Connection Management API
Mode
Description
IN
Maximum number of characters
(including NULL terminator) that
string array can contain
OUT
NULL - terminated string
Mode
Description
IN
Selected operating mode (see
Table 1-4 )