4.
Wire the detector (see Figures 4 and 7).
5.
Select the desired jumper and DIP switch settings (see
Figure 3). See section "Jumper settings" below for more
information.
6.
Remove the blinders and add the stickers, if required (see
Figure 6 for an example).
7.
For ceiling-mount applications that require a 90° coverage,
use the SB01 swivel-mount bracket.
8.
Close the cover.
9.
Insert the screw and place the custom insert.
For EN 50131 grade 3 installations, do not use mounting
position C.

Jumper settings

See Figure 3 for the jumper locations in the detector.
J1: Not used
J2: PIR enabling the LED
On: Enables the detector LED at all times (default)
Off: Puts the LED under control of the control panel and
disables the detector LED at all times (no memory feature)
J3 and J4: Dual loop setting
This sets the alarm and tamper relays. It allows you to connect
the detector to any control panel. Use jumpers 3 and 4. See
Figure 7.
J5: D/N mode (Day/Night) or Rtest (remote test) setting
Use this jumper to set terminal 8 to either D/N or Rtest.
GE Security recommends that you use D/N to manage the
AM/TF activation when required. Use Rtest to test the detector
from the control panel. The detector will activate the Alarm
relay if the test result is positive, and the AM relay if the test
result is negative.
On: Terminal 8 = D/N (default)
Off: Terminal 8 = Remote test
J6: Polarity setting of the control voltage (CV)
On: "Active High" provides the standard GE Security logic with
"Active High" logic to enable Walk Test (WT) and Day/Night
inputs (default)
Off: "Active Low" provides "Active Low" logic to enable Walk
Test and Day/Night inputs
Setting the detector: DIP switch setting
See Figure 3, item 1.
SW 1: When to signal AM (anti-masking) or TF (technical
fault) output
On: Signals AM or TF only when the system is in Day mode
(default)
Off: Always signals AM or TF during Day and Night mode
SW 2: AM sensitivity
On: Selects a higher level of AM sensitivity. AM relay reacts
within 6 seconds.
Off: Selects the standard AM sensitivity. AM relay reacts within
12 seconds (default).
SW 3: Resetting the AM/TF output
The system will only reset an AM alarm if it has ensured that
the cause of the AM alarm has been removed. If the AM
4 / 20
circuitry cannot return to its original reference levels, then
either the detector is still masked or possibly has been
damaged. The owner should then visually check that the
detector is still fully functional.
On: Resets the AM or TF status 40 seconds after a PIR alarm.
Off: Resets the AM or TF status after a PIR alarm when the
system is in Day and Walk Test status. The yellow LED will
blink quickly. When the system is in Night status, the yellow
LED will turn off and the system is reset (default).
SW 4: Signaling AM or TF output
On: Signals AM on both the AM and Alarm relays. Signals TF
on the AM relay only (EN 50131)
Off: Signals AM and TF on the AM relay (default)
SW 5: Setting LEDs
On: Enables both LEDs on the detector at all times (default).
Off: Puts both LEDs under the control of the Walk Test and
Day/Night input. This activates the memory feature of the
detector.

LED indication

PIR
Red
Yellow
LED
LED
Start up
Low voltage
PIR intruder
alarm
PIR/AM
Red
Yellow
LED
LED
Start up
Low voltage
PIR intruder
alarm
Latched PIR
(Memory)
AM alarm
After AM
reset
Technical
fault
Continuously on
Normal blinking (1 Hz)
Fast blinking (4 Hz)
* Depends on the setting of the DIP switch SW4.

Specifications

Detector
Signal processing
Range
Optical
Memory
Input power
Peak-to-peak ripple
P/N 146414999-2 • REV 2.0 • ISS 20JUL10
Alarm
AM
To reset
relay
relay
Closed
Automatically
after 25 s
Open
Apply correct
(Alarm)
voltage
Open
Automatically
(Alarm)
after 3 s
Alarm
AM
To reset
relay
relay
Closed
Closed
Automatically
after 60 s
Open
Open
Apply correct
(Alarm)
(Alarm)
voltage
Open
Automatically
(Alarm)
after 3 s
Switch to Night
mode
Open*
Open
See DIP
(Alarm)
(Alarm)
switch 3
Switch to
Night mode
Open
Do a successful
(Alarm)
walk test
VE1012
VE1012AM
PIR
PIR + AM
V2E
12 m (39 ft. 4 in.)
9 high-density mirror curtains
No
Yes
9 to 15 VDC (12 V nominal)
2 V (at 12 VDC)