9 "SINAMICS V90 PN" Demo Case
9.1 Overview of the demo case
"SINAMICS V90 PN" Demo Case
9
9.1
Overview of the demo case
9.1.1
Configuration of the case
The "SINAMICS V90 PN" demo case consists of two SINAMICS V90 drives with
the appropriate servo motors, one SIMATIC-CPU 1515T-2 PN and the ET 200SP
distributed I/O system with the respective operating elements, such as, toggle
switches, potentiometers and an emergency stop button.
Figure 9-1 "SINAMICS V90 PN" demo case
The ET 200SP distributed I/O is configured with the following modules:
Digital inputs DI 16x24V DC
Digital outputs DQ 16x24V DC / 0.5A
TM Timer DIDQ 10x24V technology module
AI 2xU analog inputs
9.1.2
Control elements
The modules of the ET 200SP distributed I/O system are connected to the demo
case with different operating and display elements, which can be used for
demonstrations:
Toggle switch to operate the digital inputs
LEDs to signal the digital outputs
TOs of S7-1500(T)