6. wheel balancinG proGramS
6.1.
operation for StD – clamp weights
6.1.1.
switch on the machine and select standard (std) mode.
6.1.2.
mount the wheel on the shaft and lock.
6.1.3.
input wheel parameter.
6.1.4.
lower down the wheel guard and the wheel will automatically
spin.
6.1.5.
At the end of the spin the machine will automatically display
imbalance values.
6.1.6.
Lift up guard and manually rotate the wheel until all inner/outer
imbalance position led's are lit.
6.1.7.
Position required balance weights and fix at the 12 o'clock
position to the rim. use foot brake to hold wheel in position.
6.1.8.
Once weights are fixed, lower down the guard and allow the
test to start again.
6.1.9.
if the test results are correct, remove wheel from shaft.
6.1.10.
if the test results are incorrect, then repeat the process until
correct.
6.2.
operation alu1 – Stick on weights
6.2.1.
switch on machine and press P4 until Alu1 balance mode
is selected on display.
6.2.2.
mount the wheel on the shaft and lock.
6.2.3.
input wheel parameter.
6.2.4.
lower down the wheel guard and the wheel will automatically
spin.
6.2.5.
At the end of the spin the machine will automatically display
imbalance values.
6.2.6.
lift up guard and manually rotate the wheel until all
inner/outer imbalance position LED's are lit.
6.2.7.
Position required balance weights and fix at the 12 o'clock
position. use foot brake to hold wheel in position. stick
weights 20mm from edge of wheel.
6.2.8.
Once weights are fixed, lower down the guard and allow
the test to start again.
6.2.9.
if the test results are correct, remove wheel from shaft.
6.2.10.
if the test results are incorrect, then repeat the process
until correct.
6.3.
operation alu2 – Stick on weights
6.3.1.
switch on machine and press P4 until Alu2 balance mode
is selected on display.
6.3.2.
mount the wheel on the shaft and lock.
6.3.3.
input wheel parameter.
6.3.4.
lower down the wheel guard and the wheel will
automatically spin.
6.3.5.
At the end of the spin the machine will automatically display
imbalance values.
6.3.6.
lift up guard and manually rotate the wheel until all
inner/outer imbalance position LED's are lit.
6.3.7.
Position required balance weights and fix at the 12 o'clock
position. use foot brake to hold wheel in position.
6.3.8.
once weights are fixed, lower down the guard and allow
the test to start again.
6.3.9.
if the test results are correct, remove wheel from shaft.
6.3.10.
if the test results are incorrect, then repeat the process
until correct.
6.4.
operation alu3 – clamp + Stick weight
6.4.1.
Switch on machine and press P4 until ALU3 balance mode
is selected on display.
6.4.2.
mount the wheel on the shaft and lock.
6.4.3.
input wheel parameter.
6.4.4.
lower down the wheel guard and the wheel will automatically
spin.
6.4.5.
At the end of the spin the machine will automatically display
imbalance values.
6.4.6.
Lift up guard and manually rotate the wheel until all inner/outer
imbalance position led's are lit.
6.4.7.
Position required balance weights and fix at the 12 o'clock
position. use foot brake to hold wheel in position.
6.4.8.
Once weights are fixed, lower down the guard and allow the
test to start again.
6.4.9.
if the test results are correct, remove wheel from shaft.
6.4.10.
if the test results are incorrect, then repeat the process until correct.