Cmos Battery; Ambient Conditions - Bosch rexroth PR30 Operating Instructions Manual

Control cabinet pc and panel pc
Table of Contents

Advertisement

8/45

Ambient conditions

5.6.1 CMOS battery

The service life of the CMOS battery of type BR2032 is 5 to 7 years.
6 Ambient conditions
Humidity
Operating temperature
Storage temperature
Shock protection
Overvoltage category
Contamination level
Mechanical strength
Tab. 6-1: Ambient conditions
The ambient air must not contain acids, alkaline solutions, corrosive
agents, salts, metal vapors and other electrically conductive
contaminants in high concentrations
The ambient air must be free from dust, housings and installation
compartments must comply with the min. degree of protection IP 54
according to DIN VDE 0470-1.
This is a product that corresponds to the limit values of the emitted
interference of class A (industrial environments), but not of class B
(residential area and small enterprises).
When using the product in residential areas or small enterprises, the
operator has to take actions to prevent radio interferences (also
refer to DIN EN 55022).
NOTICE
Due to the risk of corrosion, avoid sulphurous gases (e.g. sulphur dioxide (SO
and hydrogen suphide (H
Bosch Rexroth AG R911384706_Edition 01
PR30 and VR30 Control Cabinet PC and
85% at 40°C (non-condensing)
0 to 55°C (with airflow 0.3 m/s), 10 °C less for HDD
-20 to 60 °C
IEC 60068-2-27
2
2, no condensation allowed
IEC 60068-2-64
Acceleration: SSD 2G; HDD: 0.3G
Defective product due to gases jeopardizing
functions
S)). The product is not resistant against these gases.
2