Description of the device

3.6 Reset button

LED
P1
P2
R1
Note
Primary user (radar) on all enabled channels (only when DFS is enabled)
If the device detects competing radar signals on all enabled channels of the WLAN
interface, the F LED is lit and R1 flash. No data traffic is then possible for the next 30
minutes. After this time, the device runs the scan again and checks whether a primary
user still exists. If no primary user is detected, data traffic is possible again.
The wait time of 30 minutes is necessary due to legal requirements and cannot be
shortened even by restarting the device.
3.6
Reset button
Position
NOTICE
Loss of water and dust protection
If the cover is not mounted correctly, the device is not water and dust proof.
The reset button (position ①) is on the top of the housing:
24
Color
Meaning
Flashing red
Firmware on PLUG:
The device is performing a firmware update or downgrade.
Interval:
2000 ms
on / 200 ms off
Red
A competing radar signal was found on all enabled channels.
Simultaneous
R1 yellow flash-
ing
Flashing yellow The port LEDs flash for detection of device location.
The "LED flash" function is
Either with SINEC PNI
Or via the WBM page "Discovery and Set via DCP"
Operating Instructions, 07/2020, C79000-G8976-C325-14