Commissioning
7.3 Switching on
5. In case of uneven running or abnormal noise, switch off the machine. As the machine
runs down, identify the cause.
– If the mechanical operation improves immediately after the machine is switched off,
– If the mechanical running does not improve immediately after switching the machine
96
then the cause is magnetic or electrical.
off, then the cause is mechanical.
- Imbalance of the electrical machine or the driven machine
- The machine set has not been adequately aligned
- The machine is being operated at the system resonance point. System = motor, base
frame, foundation, ...
NOTICE
Serious damage to the machine
If the vibration values in operation are not maintained in accordance with DIN ISO
10816-3, then the machine can be mechanically destroyed.
• During operation, observe the vibration values in accordance with
DIN ISO 10816-3.
1MB..1/2/3/4 - shaft heights 63 ... 355