Panasonic PM4H-F Series Quick Manual page 6

Din48 size analog multirange power off-delay timers
Hide thumbs Also See for PM4H-F Series:
Table of Contents

Advertisement

PM4H-SD/SDM
UL File No.: E122222
CSA File No.: LR39291
48
1.890
48
1.890
CHARACTERISTICS
Item
Rated operating voltage
Rated frequency
Rated power consumption
Rating
Output rating
Operation mode
operation control time range
-
switching time
Operation time fluctuation
Time
Setting error
accuracy
Voltage error
Note:)
Temperature error
Contact arrangement
Contact
Contact resistance (Initial value)
Contact material
Mechanical (contact)
Life
Electrical (contact)
Allowable operating voltage range
Insulation resistance (Initial value)
Electrical
function
Breakdown voltage (Initial value)
Min. power off time
Max. temperature rise
Shock resistance
Mechanical
function
Vibration resistance
Ambient temperature
Operating
Ambient humidity
condition
Atmospheric pressure
Protective construction
Others
Weight
Notes: 1) Unless otherwise specified, the measurement conditions at the maximum scale time standard are specified to be the rated operating voltage, 20°C
temperature, and 1s power off time.
2) For the 2s range, the tolerance for each specification becomes ±10ms.
3) Between contacts of different poles for SDM type only.
DIN48 SIZE ANALOG
STAR ( )-DELTA ( ) TIMERS
FEATURES
• Select four types of time ranges between 0.2 s and 100 s on a single unit.
• Select between five types of time ranges between 0.04 s and 0.7 s for the
switching times.
• There is a
glance.
• The AC free power supply and shorter body make it easier to use.
mm
inch
66.5
2.618
Type
Functional
Destructive
Functional
Destructive
-
switching indicator so you can check the operation at a
PM4H-SD/SDM
100 to 240V AC, 24V AC
50/60Hz common
Approx. 10VA (100 to 240V AC)
Approx. 2.5VA (24V AC)
5A 250V AC (resistive load)
-
star-delta switching (Power ON-delay)
2s to 100s, 4 time ranges switchable
0.04, 0.1, 0.3, 0.5, 0.7s (5 time range selectable)
±0.3% (power off time change at the range of 0.5s to 1h)
±5% (Full-scale value)
±0.5% (at the operating voltage changes between 85 to 110%)
±2% (at 20°C ambient temp. at the range of –10 to +50°C
Star (
) side: Timed-out 1 Form A Delta ( ) side: Timed-out 1 Form A
Instantaneous: 1 Form A (Instantaneous for SDM type only)
Max. 100mΩ (at 1A 6V DC)
Au flash on Silver alloy
2×10
5
10
(at rated control capacity)
85 to 110% of rated operating voltage (at 20°C coil temp.)
Between live and dead metal parts
Between input and output
Min. 100MΩ
Between contacts of different poles *3
Between contacts of same pole
2,000Vrms for 1 min Between live and dead metal parts
2,000Vrms for 1 min Between input and output
2,000Vrms for 1 min Between contacts of different poles *3
1,000Vrms for 1 min Between contacts of same pole
500ms
65°C
2
Min. 294m/s
(4 times on 3 axes)
2
Min. 980m/s
(5 times on 3 axes)
10 to 55Hz: 1 cycle/min double amplitude of 0.5mm (10min on 3 axes)
10 to 55Hz: 1 cycle/min double amplitude of 0.75mm (1h on 3 axes)
–10 to +50°C
Max. 85%RH
860 to 1,060hPa
IP65 on front panel (using rubber gasket ATC18002) <only for IP65 type>
100g
3.527 oz
110g
3.880 oz
(Screw terminal type)
02/2003
PM4H-SD/SDM
+14 to
+122°F)
7
(At 500V DC)
131°F
+14 to +122°F
(Pin type)
-
68°F
ambient
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents