Huawei BTS3012 System Description
Hide thumbs Also See for BTS3012:

Advertisement

HUAWEI BTS3012 Base Station
System Description

Advertisement

Table of Contents
loading

Summary of Contents for Huawei BTS3012

  • Page 1 HUAWEI BTS3012 Base Station System Description...
  • Page 2 Document Version 02 (2006-08-11) Product Version V300R005 Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. Please feel free to contact our local office or company headquarters. Huawei Technologies Co., Ltd. Address: Administration Building, Huawei Technologies Co., Ltd., Bantian, Longgang District, Shenzhen, P.
  • Page 3 Huawei Technologies Co., Ltd. Trademarks and other Huawei trademarks are the trademarks or registered trademarks of Huawei Technologies Co., Ltd. in the People’s Republic of China and certain other countries. All other trademarks and trade names mentioned in this document are the property of their respective holders.
  • Page 4: Table Of Contents

    HUAWEI BTS3012 Base Station System Description Table of Contents Chapter 1 Introduction to BTS3012 ....................3 1.1 Position of the BTS3012 in the GSM Network..............3 1.2 Features of the BTS3012...................... 4 Chapter 2 Key Benefits of the BTS3012 ..................5 2.1 Coverage Capability ......................
  • Page 5 HUAWEI BTS3012 Base Station System Description 6.3 Software Reliability ......................19 Chapter 7 Technical Specifications....................21 7.1 Radio Specifications ......................21 7.1.1 Working Frequency Bands..................21 7.1.2 Transmit Specifications .................... 21 7.1.3 Receive Specifications ..................... 21 7.2 Engineering Specifications ....................22 7.2.1 Mechanical Dimensions ...................
  • Page 6: Chapter 1 Introduction To Bts3012

    Architecture of the GSM radio access network Note: The BTS shown in 0 can be any of the members in the Huawei BTS product family, which includes the indoor macro BTS, outdoor macro BTS, and mini BTS. You can choose the BTS type according to the actual environment and requirements.
  • Page 7: Features Of The Bts3012

    1.2 Features of the BTS3012 The BTS3012 is a new member of Huawei GSM indoor macro-cell base station family. It has excellent performance and high reliability. It holds double transceivers. One BTS3012 cabinet can support a maximum of 12 TRXs.
  • Page 8: Chapter 2 Key Benefits Of The Bts3012

    2.2 Capacity The BTS3012 has the following benefits in terms of capacity: One BTS3012 cabinet supports up to 12 TRXs. The BTS3012 supports multiple cells and one cabinet supports up to six cells. Each site supports 1 to 36 TRXs.
  • Page 9: Hybrid Combined Cabinet

    Supporting TMAs This improves the receive sensitivity. 2.7 Power Supply The BTS3012 uses the –48 V DC power supply. It supports the 110/220 V AC and +24 V DC power input through the Sidepower, which is the external power supply equipment.
  • Page 10: Chapter 3 System Architecture

    Document Title Security Level 3 System Architecture 3.1 Physical Architecture Complying with the IEC60297standard, the cabinet dimensions of the BTS3012 are as follows: Height: 1600 mm Width: 600 mm Depth: 450 mm 0 shows the BTS3012 cabinet. 2006-10-04 HUAWEI Confidential...
  • Page 11 Document Title Security Level Figure1 Front view of the BTS3012 cabinet 0 shows a BTS3012 cabinet under full configuration. 2006-10-04 HUAWEI Confidential Page8, Total35...
  • Page 12 (6) Power distribution box (7) DSAC (8) DELC0 (9) DELC1 (10) DMLC/DELC2 (11) Cabinet top subrack BTS3012 cabinet under full configuration 0 lists the boards and modules in the BTS3012. Boards and modules Board and Module Full Spelling DTRU Double Transceiver Unit DTMU Transmission &...
  • Page 13: Functional Architecture

    Monitor Signal Lightning-Protection Card for DTRU BTS DELC E1 Signal Lightning-Protection Card for DTRU BTS DSAC Signal Access Card for DTRU BTS 3.2 Functional Architecture The functional architecture of the BTS3012 is as shown in 0. Abis Monitor BITS Slave/group cabinet...
  • Page 14: Common Subsystem

    Reports alarms related to the control of the RET antenna and monitoring of the feed current. DEMU Monitors the environment. Cabinet top DMLU Provides lightning protection for the 32-route Boolean access value input and 6-route Boolean value output of the 2006-10-04 HUAWEI Confidential Page11, Total35...
  • Page 15: Double Transceiver Subsystem

    Supports the enhanced functions such as PBT, transmit diversity, and 4-way receive diversity. 3.2.2 RF Subsystem The RF subsystem comprises: RF antenna subsystem Front-end of the RF subsystem RF transceiver subsystem 0 lists the components of each part. 2006-10-04 HUAWEI Confidential Page12, Total35...
  • Page 16: System Configuration

    System Configuration The system configuration of the BTS3012 is as follows: One BTS3012 cabinet can accommodate 12 TRXs under full configuration. Under full configuration, there are six DTRUs. When a combiner is used, the cell can have up to 8 TRXs if a sector is equipped with one dual-polarization antenna or two single-polarization antennas.
  • Page 17: Chapter 4 Services And Features

    EDGE MCS1–MCS9 EGPRS packet service 4.2 Features The special features of the BTS3012 with respect to the following aspects are described here. EDGE The BTS3012 supports system information broadcast and resource indication, which are compatible with the 3GPP R99.
  • Page 18 The BTS3012 can detect whether the main boards and modules are in position. The BTS3012 can detect and report the output power of the DTRU module. Extended Cell With the extended cell function, the BTS3012 can cover an area of up to 120 km. 2006-10-04 HUAWEI Confidential Page15, Total35...
  • Page 19: Chapter 5 Operation And Maintenance

    5.1.2 Terminal Maintenance As shown in 0, local maintenance is implemented on the PC. The PC is connected to the BTS3012 through the Ethernet cable. You can operate and maintain the sites, cells, and TRXs through the local maintenance. 5.1.3 Remote Maintenance As shown in 0, remote maintenance is implemented through a PC.
  • Page 20: O&M Functions

    The alarm management function of the BTS3012 can detect and report equipment faults and abnormal functioning in a real time manner. With this function, the BTS3012 can collect, clear, query, handle, save, explain, prompt, filter, and analyze the alarm. In addition, the online help and layered alarm filtering function help you to quickly locate faults and provide fault recovery methods.
  • Page 21: Chapter 6 Reliability

    Optimized fault detection of boards and system Optimized fault isolation Redundancy The BTS3012 uses the redundancy design. The key clock bus, control bus, data bus, DTMU modules use 1+1 backup mode. The transceivers mutual aid is also supported. System Monitoring The BTS3012 can automatically detect and diagnose faults in the hardware or software and report them in form of alarms.
  • Page 22: Software Reliability

    The boards provide protection against reverse-polarity connection. Excellent Lightning Protection Design The BTS3012 needs no external lightning protection device. The antenna ports of the DDPU have the 8KA/40KA lightning protection capability. The lightning protection of the BTS3012 is implemented by directly connecting the conductor inside the DDPU antenna ports to the ground.
  • Page 23 The system records user operations within a certain period and saves the recorded information to the system operation logs. The operation logs can be used to locate the error or exception because of incorrect operation so that the system can be restored to the normal state. 2006-10-04 HUAWEI Confidential Page20, Total35...
  • Page 24: Chapter 7 Technical Specifications

    Document Title Security Level 7 Technical Specifications 7.1 Radio Specifications 7.1.1 Working Frequency Bands 0 lists the working frequency bands of the BTS3012. BTS3012 working frequency band Frequency Band Parameter Specification 900 MHz Receive band 876 MHz to 915 MHz...
  • Page 25: Engineering Specifications

    Full configuration (S4/4/4, with transmission and DCOM modules) 7.2.3 Power Supply The –48 V DC power supply of the BTS3012 complies with the requirement in the ETS 300 132-2. 0 lists the standard of the input power supply. 2006-10-04 HUAWEI Confidential...
  • Page 26: Power Consumption

    Document Title Security Level The BTS3012 cabinet supports 220 V AC or +24 V DC input power through the external power cabinet such as the Sidepower. Power requirements Input Power Supply Value Rated voltage –48 V DC Input voltage range From –40 V DC to –60 V DC...
  • Page 27: Operation Environment

    (EMI). n interface Antenna feeder interface RF signal It is the input interface for the antenna feeder 7.2.6 Operation Environment 0 shows the BTS3012 operation environment requirements. BTS3012 operation environment requirements Operation Type Item Range Long-term Temperature –5°C to +45°C...
  • Page 28: Emc

    Storage Environment The BTS3012 complies with ETS class 1.2 Weather Protected, Not Temperature Controlled Storage Locations in ETS 300 019-1-1. 7.2.10 Transportation Environment The BTS3012 complies with ETS class 2.3 Public Transportation in ETS 300 019-1-2. 2006-10-04 HUAWEI Confidential Page25, Total35...
  • Page 29: Appendix A Technical Specifications

    Document Title Security Level Appendix A Technical Specifications A.1 ITU and ETSI Standards Huawei-developed BTS is in compliance with GSM recommended phase 2+ of ETSI, as shown below: GSM 01.02(ETR009):"general description of a GSM Public Land Mobile Network (PLMN)" GSM 04.04 (ETS 300 553):"European digital cellular Telecommunications System (phase 2);...
  • Page 30: Abis Interface And Um Interface Specifications

    Base Station System - Mobile-services Switching Centre (BSS - MSC) interface" A.3 Environment Adaptability Specifications BTS3012 Specifications are as follows: Low temperature working index: IEC 68 2-1. High temperature working index: IEC 68 2-2. Temperature cycle operation test: IEC 68 2-14.
  • Page 31: Lightning Protection Specifications

    ITU-T K.11 principles of protection against overvoltage and overcurrents. ITU-T K.46 protection of telecommunication lines using metallic symmetric conductors against lightning induced surges. ITU-T K.20 resistibility of telecommunications equipment installed in a telecommunications centre to overvoltages and overcurrents. A.6 Safety Standard EN60950. IEC60950. 2006-10-04 HUAWEI Confidential Page28, Total35...
  • Page 32: Appendix B Acronyms And Abbreviations

    Dual Duplexer Unit for DTRU BTS DEMU Environment Monitoring Unit for DTRU BTS DELC E1 Signal Lightning-Protection Card for DTRU BTS DGPS GPS processing unit for DTRU BTS Data Link (layer) DMLC Monitor signal Lightning-protection Card for DTRU BTS 2006-10-04 HUAWEI Confidential Page29, Total35...
  • Page 33 ISDN Integrated Services Digital Network Layer 1 Layer 2 L2ML Layer 2 Management Link Layer 3 LAPB Location Area LAPD Link Access Protocol on the D channel LAPDm Link Access Protocol on the Dm channel 2006-10-04 HUAWEI Confidential Page30, Total35...
  • Page 34 Power Supply Unit RACH Random Access Channel Remote Electric Tilt Radio Frequency Radio Resource management Radio Signaling Link RXLEV Received signal level RXQUAL Received signal Quality SACCH Slow Associated Control Channel SACCH/C4 Slow Associated Control Channel/SDCCH/4 2006-10-04 HUAWEI Confidential Page31, Total35...
  • Page 35 Transmission Extension power Supply unit Transmission Extension Unit TMSI International Mobile Subscriber Identity Timing/Transmission and Management Unit Transceiver unit TRAU Transcoder and Rate Adaptor Unit Time Slot Voice Activity Detection Visitor Location Register Work Station 2006-10-04 HUAWEI Confidential Page32, Total35...

Table of Contents