Contents Contents About This Document (HL-C1-WL Series)..........1 Precautions for the Handling Class 3B Laser Beam......1 Conditions for Compliance with EMC Directives in EU......8 CHAPTER 1 NAME AND FUNCTION OF EACH PART 1-1 Controller ..................1-1 CHAPTER 2 INSTALLATION OF SENSOR HEAD 2-1 Mounting Dimensions..............2-1...
About This Document (HL-C1-WL Series) This document (HL-C1-WL Series) describes modifications, additions and deletions to the HL-C1 Series. Read the USER’S MANUAL for the HL-C1 Series to check the descriptions in this document. Precautions for the Handling Class 3B Laser Beam 1.
Page 5
Safety Equipment 1) Key Switch This product uses a key switch to emit a laser. Remove the key when the product is not used. 2) Beam attenuator If there is danger of incision by the laser beam into eyes during work, install the accessory beam attenuator.
Page 6
4)Laser Emission Indicator The green LED of the sensor head lights up for about five seconds before the laser is emitted. It is possible to recognize the LED through the laser protective eyewear. レーザ放射表示灯 Laser emission indicator Summary of IEC 60825-1 Safety measures to be taken by the user according to the class of the laser product are shown below.
Page 7
Classification Requirements subclause Class 1 Class 1M Class 2 Class 2M Class 3R Class 3B Class 4 Scanning 4.10 Scan failure shall not cause product to exceed its classification Class label Required wording Figures 14 and 15 and required wording 5.1 to 5.6 Aperture label 5.7 Not required...
Page 8
2. FDA Export to US To export the laser product to the US installed on equipment, it is restricted by the regulation of the USA Food and Drug Administration (FDA). In case this product is used as a FDA conformity product, be sure to change the warning label to the English version label and affix the Certifi- cate/identification label, which are enclosed in the package of this product.
Page 9
Be sure to affix the following labels to the positions shown in the figure below (1) Warning label (2) Certificate/identification label <Label position>...
Conditions for Compliance with EMC Directives in EU To meet requirements of EMC directives of the EU, connect ferrite cores (ZCAT3035-1330 made by THK Co., Ltd.) to the cables connected to the terminal block, as shown below. LASER BRIGHT D ARK N O T USE COM .
CHAPTER 1 NAME AND FUNCTION OF EACH PART 1-1 Controller 1) Laser emission indicator (green) LASER BRIGHT 2) BRIGHT indicator (red) D ARK N O T USE 3) DARK indicator (red) ...
Page 13
CHAPTER 1 NAME AND FUNCTION OF EACH PART 1)Laser Emission Indicator (green) The indicator lights up during emission and for about five seconds before the laser beam is emitted from the sensor head 1 or sensor head 2. 2)BRIGHT Indicator (red) The indicator lights up when sensor head 1 or sensor head 2 cannot make a measurement due to excessive light.
Page 14
CHAPTER 1 NAME AND FUNCTION OF EACH PART -MEMO-...
CHAPTER 2 INSTALLATION OF SENSOR HEAD 2-2 Mutual Interference Area If more than one sensor head is mounted close together, no mutual interference will occur if the neighboring sensor's laser spot is outside the shaded area in the figure below. Mount other sensor heads so laser spots do not enter the shaded area.
CHAPTER 2 INSTALLATION OF SENSOR HEAD 2-3 Beam Diameter HL-C135C-BK10 2-4 Output Characteristics and Measurement Range Indicator Lights Blinks Blinks Measurement range indicator Measuring range Measurement center distance Displacement output 20mA 12mA Distance(mm) 350mm type Open Alarm output Closed (N.C.) With initial analog output setting...
CHAPTER 3 INPUT TERMINAL 3-1 Input Terminal NPN output type Symbol Description I L1 LASER Remote interlock (sensor head 1) BRIGHT I 11 D ARK Zero set ON input (sensor head 1) N O T USE I 12 Zero set OFF input (sensor head 1) ...
CHAPTER 3 INPUT TERMINAL 3-2 Remote Interlock Terminal Remote Interlock Input Terminal IL1 and IL2 are remote interlock input terminals of sensor head 1 and sensor head 2. Short circuit these remote interlock input terminals with the (-) terminals (NPN output type) to emit the laser to start measurement.
Page 22
CHAPTER 3 INPUT TERMINAL HL-C1C-M-WL (Photo MOS output type) emits laser beam for measurement when the voltage is applied to the remote interlock terminal and COM terminal. In the state of the factory setting, this product does not start measurement since the remote interlock terminal is not connected.
CHAPTER 4 DESCRIPTION OF MODIFIED FUNCTIONS 4-1 Description of Modified Functions The functions modified, deleted or added for the HL-C1-WL Series from those of the HL-C1 Series are as follow. Description Function item HL-C1 Series HL-C1-WL Series Diffused reflection mode only. The specular reflection Measurement mode may not be selected.
CHAPTER 4 DESCRIPTION OF MODIFIED FUNCTIONS 4-2 Setting Range and Initial Value The setting ranges and initial values changed for the HL-C1-WL Series from the HL-C1 Series are as follow. HL-C1 Series HL-C1-WL Series Initial value Initial value Function item...
LD emission (Laser beam Stopped emission control) 1 The "timing" function is deleted in HL-C1-WL Series. Do not send or receive this command. 2 The format of the "calibration shift" command has been changed. Refer to 4-2-2. 4-4-2 Command with Modified Format With HL-C1C-WL, the format of the "calibration shift"...
CHAPTER 5 SPECIFICATIONS 5-1 Sensor Head Model No. HL-C135C-BK10 Measuring type Diffused reflective type Measurement center 350mm distance Measurement range 200mm Visible semiconductor laser Light source (Wave length 658nm, 10mW max. class 3B) Beam diameter ( 1) 400 x 200 m approx. Light receiving Linear image sensor element...
CHAPTER 5 SPECIFICATIONS 5-2 Controller Model No. HL-C1C-WL HL-C1C-M-WL Supply voltage 24V DC 10%, incl. ripple 0.5V (P-P) Current With 2 sensor heads: 550mA approx. consumption With 1 sensor head: 430mA approx. Sampling period 100 S,144 S, 200 S, 255 S, 332 S, 498 S, 1000 S Serial input/output RS-232C Temperature...
Page 30
CHAPTER 5 SPECIFICATIONS Laser Green LED (Lights up during or immediately before emission of emission laser from sensor head 1 or 2) indicator BRIGHT Red LED (Lights up upon measurement failure of sensor head indicator 1 or 2 due to excessive light amount) DARK Red LED (Lights up upon measurement failure of sensor head indicator...
CHAPTER 5 SPECIFICATIONS 5-3 Compact Console Model No. HL-C1DP1(-E)-WL Supply voltage 24V DC 10%, incl. ripple 0.5V (P-P) Current consumption 200mA or less Displaying STN monochrome LCD element Measurement -999.9999 to 999.9999 display range Back light White LED Life of LCD Average 50,000 hours (Note 1) Operation force 0.5N or less...
As for all models, please contact our office. Contact for CE <Until June 30 ,2013> Panasonic Electric Works Europe AG Rudolf-Diesel-Ring 2, D-83607 Holzkirchen, Germany <From July 1 ,2013> Panasonic Marketing Europe GmbH Panasonic Testing Center Winsbergring 15, 22525 Hamburg,Germany...