ctrlX HMI DE0015, DE0021 Multi-Touch
Displays (Housing Devices)
5. Press the "Home" key to confirm the selection.
6. Press the "i" key to toggle to "Exit".
7. Press the "Home" key for confirmation purposes.
If the touch function is disabled via "Always Off" or "Off for 60 sec",
the status LED flashes green on the front while it is disabled.

12.2 Operating and error display

A status LED is positioned in the lower area of the front plate.
Symbol, LED Display
Power
LED green
LED off
LED orange
Tab. 12-1: Status LED for operating and error display on the front panel

13 Error causes and troubleshooting

For information on the error display on the front panel, refer to
"Operating and error display " on page 37
Error
No image visible
Distorted display due to incorrect dis-
play resolution
"NO SIGNAL" on the display
Tab. 13-1:
Error causes and troubleshooting
Description
Normal mode
No supply voltage of 24 V DC
No screen signal present
Connected control cabinet PC
is booting
Correction
Connect the supply voltage and check the X1S1 connec-
tion
Connect the display port or CDI+ cables correctly
If panels with display port are used, use only Bosch
Rexroth display cables to connect the panels, refer to
chapter 5.5 "Connecting cables of the display port" on
page
8.
Set the correct display resolution in the graphic driver.
The standard resolution of the Windows images (also for
the recovery sticks) is FullHD (1920 × 1080). Set the
correct value once when displays with a smaller resolu-
tion are used
Restart the control cabinet PC
Check the cabling of the graphic interface.
Check the selected video interface and correct the setting
in "On Screen" menu if required. Setting upon delivery:
"RX" (for XCDI+rx).
Error causes and troubleshooting
Action
-
Check the supply voltage
Check video connection
Wait until the system completed
booting
R911405731_Edition 02 Bosch Rexroth AG