Diesel & fluid flow meter

Advertisement

Quick Links

thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly
maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.
USE THIS PRODUCT CORRECTLY AND ONLY FOR ITS INTENDED PURPOSE. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY
AND WILL INVALIDATE THE WARRANTY. RETAIN THESE INSTRUCTIONS FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
 Maintain the meter in good condition (use an authorised service agent).
 replace or repair damaged parts. Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
 Keep the meter clean for the safest and best performance.
 Ensure that a fuel filter is securely attached to any pick up pipe so that unfiltered fuel is not taken through the meter.
 Wear safety goggles, gloves and protective clothing when working around fuel. A full range of personal safety equipment is available from your
local sealey dealer.
 use the meter in a suitable work area. Keep area clean and tidy and free from unrelated materials and ensure there is adequate lighting.
 Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.
 Keep children and unauthorised persons away from the work area.
 DO NOT use the meter and any associated pump where explosive or flammable vapours may be present.
 WARNING! DO NOT pump the following fluids through the flow meter: Petrol, flammable liquids with Flashpoint <55°C, water, liquids with
viscosity >20 cSt, corrosive chemicals and solvents.
2. INTRODUCTION AND SPECIFICATION
Introduction:
Volumetric nutating disc meter with three digit resettable display and six
digit total display. unique filter and flange assembly allows meter to be
positioned in four configurations. suitable for use with all sealey brand
diesel & fluid transfer pumps.
Specification:
Working pressure: ................................................................... 0.1 - 3.5 Bar
operating temp: ......................................................................-10 to +50ºc
Precision: .......................................................................................... +/- 1%
flow rate: .............................................................................20 - 80 ltr/min
Partial Indicator:......................................................................... max 999 ltr
total indicator: ..................................................................... max 999999 ltr
resolution:..........................................................................................0.1 ltr
Weight: ............................................................................................... 1.5kg
Accessories:
A
- swivel adaptor
C
- outlet connector
3. INSTALLATION
3.1
Installation options.
the tP91300.V2 flow meter can be used in both gravity fed
systems (see fig.2) and circuits with motor pumps (see fig.3) or
manual circuits equipped with a by-pass (not illustrated). In any
particular installation, attention must be paid to the direction of flow
through the meter as indicated by the moulded in arrows on the
back of the unit. If the required installation will result in the meter
readout being upside down it is possible to turn the face through
180º to correct this situation as described below.
3.2
slide the reset knob from its shaft.
3.2.1 undo both small crosshead screws at the sides of the plastic body.
3.2.2 undo the four allen headed bolts at the back of the meter (fig.4)
and prise off the back of the meter and rotate through 180°
3.2.3 reassemble in the reverse order of the above.
B
- Pump connector
fig.1
Original Language Version
InstructIons for:
DIESEL & FLUID FLOW METER
TP91300.V2
MoDEL no:
3.2.4 following installation and setting, (see section.3.3) the meter is
ready for use. to reset the partial counter to zero, rotate the reset
knob clockwise.
3.2.5 constructed for operation at a maximum pressure of 3.5 bar (50
PsI), the meter must be mounted in a such way that no unfiltered
liquid or air is pumped through it. In the case of gravitational
systems (without pumps), there must be a difference in height of at
least 1 metre between the outlet of the tank and the delivery gun
to ensure optimum operation.
fig.2
fig.3
tP91300.V2 Issue: 1 - 18/07/11

Advertisement

loading

Summary of Contents for Sealey TP91300.V2

  • Page 1 TP91300.V2 MoDEL no: thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.
  • Page 2 Mounting to a pump. (fig.3 & 5) 3.3.1 the tP91300.V2 flow meter can be directly mounted onto a pump outlet as shown in fig.6. 3.3.2 Before mounting the pump, check the required direction of flow and if necessary rotate the face of the meter as described in section 3.2.
  • Page 3 Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk, email sales@sealey.co.uk or phone 01284 757500. NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.