(6) Confirms of initialization completing message
When restart a camera, initializing action is performed in a camera. After finishing the initialization,
error code is returned to Response Window. Confirm the upper four digits of error code become to 0
(finished normally).
n
. When error code appears except 0000h, unusual may occurs in a camera. Therefore, repair it in
reference of Table. 3.
. Initialization imply that the unit performs the relative operation during turn ON the power of the
unit.
Error code Contents of error
0000
Successfully initialized
0400
EEPROM data is not written yet or disabled
1800
Cannot detects a Pan reset sensor
1a00
Cannot move to a Pan HOME position
2800
Cannot detects a Tilt reset sensor
2a00
Cannot move to a Tilt HOME position
0c01
Camera block not properly connected
(Cannot communication)
0c02
Camera block not properly connected
(Cannot communication)
0c03
Cannot drive the camera block zooming
0c05
Cannot initialized the camera block
3. Hall Sensor Detection Adjustment
When firmware version of the unit is 1.02 and later, perform the following adjustment
(1) Transmission at 8101062213FF (Receiving of debug command enabled)
Commands of 9041FF and 9051FF are returned to Response Window.
(2) Transmission at 8101061F03FF (Receiving of adjustment command enabled)
Commands of 9041FF and 9051FF are returned to Response Window.
(If this item continue performing to Section 2-4-2. Item 2, this may be omitted)
(3) Transmission at 8101061C24FF (Hall sensor detection starts simultaneously with pan and tilt)
Command of 9041FF is returned to Response Window.
After that, it performs pan and tilt operations automatically and detects the hall sensor position.
(4) When completing of measurement, command of 90510xFF is returned to Response Window.
When error code x appears 0h, measurements are completed normally. Only this state, hall sensor
data is stored in EEPROM.
n
When error code appears except 0h, it may cause by failure of adjustment operation or a camera
operates abnormally. If required, perform repair and readjustment. When turn off the power once,
repeat above steps (1) to (4).
EVI-D100/EVI-D100P
Possible cause
EEPROM uses a new article device or failure
. Reset sensor improperly connected
. Incorrect or large friction of pan and tilt mechanism
. Pan and tilt operations are stopped by any obstruction
Camera block improperly connected
(FFC improperly inserted)
Camera block has failed
Table 3 Initialization Completing Message