Precautions for connection
. For the controller and routing switcher that are used as the primary station, set the S/P selector switch
on the CPU board (on the CA board for the IXS-6700/IXS-6600) to the "P" position.
. For the controller and routing switcher that are used as the secondary station, set the M/S switch (S/P
selector switch in the IXS-6700/IXS-6600) on the CPU board (on the CA board for the IXS-6700/IXS-
6600) to the "S" position.
. A primary station can control up to 253 secondary stations.
. A single S-BUS line can be connected to up to 128 secondary stations.
. The maximum length of a single S-BUS line cable is 500 m (when the BELDEN 8281 cable is used).
. Terminate the L-type and Y-type bridges that is connected to the last machine of the S-BUS line with a
75 Z terminator. Also, terminate the unused REMOTE1 connector of each switcher with a 75 Z
terminator.
. In the primary controller or routing switcher, two or more REMOTE 1 connectors can be used.
. In the secondary controller and routing switcher, only one REMOTE 1 connector can be used each.
How to use the L-type and Y-type bridges
The L-type and Y-type bridges are supplied with the BKS-R1617A/BKS-R3219A. Use the L-type and Y-
type bridges as follows.
BKS-R1617A/R3219A
(rear panel block)
1-6
REMOTE1
(BNC-type connector, Male)
Y-type bridge
L-type bridge
BKS-R3219A/R1617A I&SSM