Panasonic FY-E15PM1 Operation Instruction Manual

Energy recovery ventilator

Advertisement

Operation Instruction
(Please be sure to give them to customer)
FY-E15PM1
FY-E15PM1L
1 book
··················
FY-E25PM1
FY-E25PM1L
CONTENTS:
SAFETY PRECAUTIONS
INSTALLATION CAUTIONS
OPERATING REQUIREMENTS
FEATURES
·······································
OPTIONAL ACCESSORIES
PART NAME AND DIMENSIONS
HOW TO INSTALL
TEST RUN
·······································
OPERATION
·····································
USE AND MAINTENANCE INSTRUCTIONS
HOW TO MAINTENANCE
WIRING DIAGRAM
TROUBLESHOOTING
SPECIFICATIONS
FY-E35PM1
FY-E35PM1L
··························
···················
···················
······················
············
·······························
···················
··························
···························
BACK COVER
····················
3
4 7
8
9
9
10 13
14
15
15
16 18
···
18 20
21 23
23

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic FY-E15PM1

  • Page 1 FY-E15PM1 FY-E25PM1 FY-E35PM1 FY-E15PM1L FY-E25PM1L FY-E35PM1L CONTENTS: SAFETY PRECAUTIONS ·························· INSTALLATION CAUTIONS ··················· OPERATING REQUIREMENTS ··················· FEATURES ······································· OPTIONAL ACCESSORIES ······················ 10 13 PART NAME AND DIMENSIONS ············ HOW TO INSTALL ······························· TEST RUN ······································· OPERATION ····································· 16 18 USE AND MAINTENANCE INSTRUCTIONS ···...
  • Page 2 Please read these instruction carefully before attempting to install, operate or service the panasonic product. Please carefully read “INSTALLATION CAUTIONS”(P. 4~7) of this instructions before installation. Failure to comply with instructions could result in personal inury or property damage. Please explain to users how to operate and maintain the product after instruction, and this booklet should be presented to users.
  • Page 3: Safety Precautions

    SAFETY PRECAUTIONS <must be complied> This product is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the product by a person responsible for their safety. Children should be supervised to ensure that they do not play with the product.
  • Page 4: Installation Cautions

    INSTALLATION CAUTIONS Carry out the installation accurately in line Don’t use the power besides the alternate with this instruction. current 220V/50Hz. It may cause the fire and electric shock. Improper practice of installation could cause an electric shocks or a fire. Ground connection.
  • Page 5 Please install the anti-bird net or similar Install the outdoor duct in a falling gradient thing in air duct. towards the outside so as to prevent water from coming in. Please remove the abnormities such as bird net, otherwise it may cause the lack of Otherwise, the building is likely to be oxygen in room.
  • Page 6 Please avoid the following duct installation. (1) excessive bending (2) multi-times bending (3) reduction the diameter of connecting duct It may cause the unexpected accident. Please don’t install the unit in location Provide an exclusive circuit breaker that where indoor temperature is below the can completely contacts on all the poles outdoor temperature.
  • Page 7 Don’t install it in the following locations. Locations exposed to high temperature or direct Locations with high humidity. flame. Do not install in high humidity locations such as bathrooms. Avoid installing the ERV in locations which reach Dew occurred in unit may cause electric shock, short circuit, temperature of 40 or above.
  • Page 8: Operating Requirements

    OPERATING REQUIREMENTS Outdoor air condition Temperature range -10 ~40 relative humidity 85% or less. Indoor air condition Temperature range -10 ~40 relative humidity 85% or less. Installation requirements: same as the indoor air conditions. The product is forbidden to use in locations where ambient temperature may sharply vary, even if it falls into range of specified usage temperature.
  • Page 9: Optional Accessories

    OPTIONAL ACCESSORIES Please contact the dealer to purchase. Filter Model Filter FY-E15PM1 FY-FPE15M1 FY-E15PM1L FY-E25PM1 FY-FPE25M1 FY-E25PM1L FY-E35PM1...
  • Page 10 PART NAME AND DIMENSIONS Part Name side inspection cover outdoor filter heat exchange core outdoor filter switch box model label indoor filter bottom inspection cover outdoor filter bottom inspection cover FY-E**PM1(right type) FY-E**PM1( model label heat exchange core switch box side inspection cover indoor filter outdoor filter...
  • Page 11 2. It's available to only reserve the side inspection opening. 3. It's also required to reserve side inspection opening in case bottom inspection opening is reserved. You can't conduct the maintenance without reservation of side inspection opening. FY-E15PM1 Suspension point dimension Dimension of inspection opening...
  • Page 12 PART NAME AND DIMENSIONS Unit:mm Cautions for inspection opening 1. Inspection opening must be reserved on ceiling so that you can perform the routine maintenance for heat exchange core and filter or checking of products. 2. It's available to only reserve the side inspection opening. 3.
  • Page 13 PART NAME AND DIMENSIONS Unit:mm Cautions for inspection opening 1. Inspection opening must be reserved on ceiling so that you can perform the routine maintenance for heat exchange core and filter or checking of products. 2. It's available to only reserve the side inspection opening. 3.
  • Page 14: How To Install

    Install 4 ceiling suspension bolts (separately buy:M10) Unit:mm FY-E**PM1 FY-E**PM1L Please align the ceiling suspension part of main Model unit with ceiling FY-E15PM1 suspension bolts. FY-E15PM1L FY-E25PM1 FY-E25PM1L FY-E35PM1 1045 FY-E35PM1L Please adjust the length of ceiling suspension bolt to ensure the distance...
  • Page 15: Operation

    TEST RUN After completion, please check the wire connection first and then perform the trial operation. Please check the status of damper and change of air volume when power is on. Switch Ventilation/stop On/Off Air volume High/low Check if air volume is changed. Heat exchange Damper Heat exchange (see the damper closed by opening side maintenance opening)
  • Page 16: Use And Maintenance Instructions

    USE AND MAINTENANCE INSTRUCTIONS Do not use it together with open-burning Please entrust the dealer or similarly appliance (heater). qualified person to repair the product excluding filter maintenance. Professional ventilation should be used when gas or oil stove is used in room. Otherwise it may cause the fire, electric shock and injury.
  • Page 17 Please stop the product immediately and Don’t use the unit near the combustible contact with dealer or similarly qualified spray. person to repair it when abnormal operation is found like noise, vibration or burnt smell. It may cause the fire. The appliance is forbidden to operate without filter.
  • Page 18: How To Maintenance

    Turn on /off the switch correctly. It must operate with filter. It’s forbidden to use the normal ventilation for the dew will be produced in and indoor air inlet if If repeatedly turning on or off the If not using the filter, heat exchange operating the mode normal switch not only cause the wrong core is clogged with dirt and dust,...
  • Page 19 HOW TO MAINTENANCE Filter maintenance - side inspection method 1.Removal of side inspection cover Remove the screws fixed on side inspection cover with screwdriver. Take the side inspection cover out toward the arrow “A” by rotating the butterfly bolt by 90° heat exchange core butterfly bolt fixed screws...
  • Page 20 HOW TO MAINTENANCE Filter maintenance - bottom inspection method (When setting the down maintenance cover, meanwhile you must reserve the side maintenance cover in advance.) 1.maintenance method for indoor filter (1) Remove the screws fixed on bottom inspection cover with screwdriver. Take the bottom inspection cover out toward the arrow “A”.
  • Page 21: Wiring Diagram

    WIRING DIAGRAM Wiring diagram Main Unit Supplied Orange Air Conditioner Power for Air Contact point a Brown without voltage Conditioner Black Black Black 220V ~ 50Hz Black Relay 3 Brown Damper Blue controller for Motor Black air conditioner Damper Blue Black Black Black...
  • Page 22 WIRING DIAGRAM As to wire for use to link power supply cord with switch, please firmly connect wire with terminal with torque force1.2N·m below and ensure the joint doesn't work loose and no solder is attached on the conductor of power supply cord.
  • Page 23: Troubleshooting

    WIRING DIAGRAM Fix the cover of switch box. cord bushing After completing the wire connection, fix the cover of switch box by the screws. (Dust and moisture may cause the electric leakage or fire.) TROUBLESHOOTING Situation Solution Is the breaker in the mode off ? The unit doesn’t works when turning on the switch.
  • Page 24: Specifications

    In case other conditions remain unchanged, noise will be up by 1.5dB(A) when measured in the half anechoic room. Panasonic Corporation Printed in China Web site: http://www.panasonic.com Issue date: 07/2019 Panasonic Corporation 2019 E15PM1853...

This manual is also suitable for:

Fy-e25pm1Fy-e35pm1Fy-e15pm1lFy-e25pm1lFy-e35pm1l

Table of Contents