en Troubleshooting
Fault
"E:36 / -25 / -26"
flashes.
flashes.
lights up.
flashes.
All other error codes.
The appliance is not work-
ing.
48
Cause
Drain pump is blocked.
The water pressure is low.
The filters in the water inflow
are blocked.
The tap is turned off.
The water inlet hose is
kinked or jammed.
The automatic voltage con-
trol system detects an unau-
thorised voltage under-us-
age.
Voltage under-usage may
cause extension of a pro-
gramme.
Voltage under-usage may
cause extension of a pro-
gramme.
The temperature is too high.
Water level is too high.
Laundry is caught in the
door.
Door is not closed.
Malfunction
The mains plug of the power
cord is not plugged in.
The circuit breaker is faulty.
Troubleshooting
→ "Cleaning the drain pump",
Page 42
No remedial action possible.
"Clean the filters in the water in-
flow" → Page 45.
Turn on the tap.
Ensure that the water inlet hose is
not kinked or jammed.
No remedial action possible.
Note: If the power supply is stable, the
programme continues to run as nor-
mal.
No remedial action possible.
No remedial action possible.
Wait until the temperature has
dropped.
→ "Cancelling the programme",
Page 37
Start the Drain programme.
Open the door again.
1.
Remove any trapped laundry.
2.
Close the door.
3.
Press Start/Reload to start the pro-
4.
gramme.
Close the door.
1.
Press Start/Reload to start the pro-
2.
gramme.
Call the after-sales service.
→ "Customer Service", Page 57
Connect the appliance to the power
supply.
Check the circuit breaker in the
fuse box.