Install RTD Probe:
7. Install RTD and connect wiring to connector block J7 on the XFC
board. The XRC board does not have RTD inputs. (See Figure 5)
Install Battery(s):
8. Verify that Memory Backup is Enabled. This is J13 on the XFC and
J1 on the XRC. (See Figures 5 & 6)
9. Mount and connect a fully charged battery to J1 on the XFC board or
J16 on the XRC board. The connectors are located in the same
position on both boards. (See Page 7 & Figures 5 & 6)
10. The display should go quickly through the startup routine then start
scrolling through the default display items. (If not, see Tip on Page
19) This typically insures that the components and wiring are good.
Refer to "Standard Displays" on page 15 for typical default displays.
Refer to "Visual Alarm & Status Codes" on page 16 for location,
symbols, and descriptions. You should see a
(upper right) annunciator since the charging source has not been
connected. This is the typical annunciator for the I/O Subsystem but
could possibly vary on different systems.
Install Solar Panel:
11. Assemble, mount, and connect solar panel or AC charger.
NEVER CONNECT CHARGER WITH THE MAIN BATTERY PACK
DISCONNECTED. (See pages 8 & 9) The
after the charging source is connected. Solar powered units will
naturally depend on available sunlight.
Setup:
12. Connect FS/2 or laptop running PCCU32 to the unit. To use an FS/2,
system must have been ordered from factory as single tube
application and with FS/2 support. PCCU32 must have software
Version 4.3 or higher and FS/2 must be 2018583-007 or higher.
13. Set date/time, ID, location and AGA setup using Entry Mode in
PCCU32 or an FS/2.
14. In Calibration Mode, verify registers for Static pressure, Differential
pressure and Temperature. (PCCU32 Only)
15. In Calibration Mode, select RTD Installed, un-check Use Fixed TF,
and adjust RTD Bias if a temperature standard is used.
16. In Calibration Mode, perform as found calibration checks.