Electrical Connection - GE AUH2436ZGDA Installation Instructions Manual

Split type heat pump
Table of Contents

Advertisement

Available languages

Available languages

Installation Instructions
Electrical Requirements
Control Wiring
Using 18 Gauge Solid Core Copper Wire
1. Cut back the insulation 1" from the end of the wire.
2. Remove the screw from the terminal block, and wrap the
wire around the screw.
3. Return the screw and wire to the terminal block and
tighten securely.
Stranded Wire
1. Cut back the insulation 3/8" from the end of the wire.
2. Make sure the round or forked terminal connector is
rated for the amperage of the unit being installed.
3. Use a crimping tool only to fasten the connector to the
wire.
4. Return the screw and connector to the terminal block
and tighten securely.
Solderless
Terminal
16

Electrical Connection

Model
Power Supply
AUH2436ZGDA
208/230V-1Ph-60Hz
AUH4860ZGDA
208/230V-0Ph-60Hz
Jacket / Insulation
Recommended breaker size
(A)
35
45
Wiring Connections
1. High and low voltage wires should be led through
different rubber rings of the electric box cover.
2. High and low voltage wires should be secured
separately. Secure the former ones with large clamps
and the latter ones with small clamps.
3. Use screws to tighten high and low voltage wiring on the
terminal board. Improper connection may create a fire
hazard.
4. Ground the units by connecting the ground wire.
5. All wiring must comply with local and national code.
Screw with
Special Fastener
Round
Terminal
How to Remove or Reinstall the Electric
Box Cover:
Remove the electric box cover :
1. First remove the top cover screws and move upward to
remove the top cover.
2. Then remove the screws of the maintenance cover, push
down the cover by hand until the tabs of the cover move
to the bottom of the slot, and then remove the cover;
3. Put back the electric box cover:
4. First align the four tabs with the corresponding slots, and
then force push up, when all the claws are pushed to the
top of the slot, install the screws.
5. Then install the top cover, align the four corners and press
down until the top cover falls to the specified position,
and finally install the screws.
Terminal
Board
Wire
31-5000483 Rev. 2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Auh4860zgda

Table of Contents