BASIC OPERATION
Parameter Name
Torque control
integral time 2
835
(current loop integral
time)
Torque detection
837
filter 2
Analog input offset
849
adjustment
Terminal 4 function
858
assignment
Torque current/Rated
859
PM motor current
Second motor torque
860
current/Rated PM
motor current
864
Torque detection
Torque monitoring
866
reference
867
AM output filter
Terminal 1 function
868
assignment
869
Current output filter
Speed detection
870
hysteresis
Input phase loss
872
protection selection
874
OLT level setting
Regeneration
882
avoidance operation
selection
Regeneration
883
avoidance operation
level
Regeneration
avoidance at
884
deceleration detection
sensitivity
Regeneration
avoidance
885
compensation
frequency limit value
Regeneration
886
avoidance voltage
gain
888
Free parameter 1
889
Free parameter 2
Cumulative power
891
monitor digit shifted
times
892
Load factor
Energy saving monitor
893
reference (motor
capacity)
Control selection
during commercial
894
power-supply
operation
Power saving rate
895
reference value
*2
For FR-F846-01160(55K) or lower
*3
For FR-F846-01800(75K) or higher
28
Setting Range
Initial Value
9999
0 to 500 ms, 9999
9999
0 to 0.1 s, 9999
100%
0 to 200%
0, 4, 9999
0
0 to 500 A,
*2
9999
9999
0 to 3600 A,
*3
9999
0 to 500 A,
*2
9999
9999
0 to 3600 A,
*3
9999
150%
0 to 400%
150%
0 to 400%
0.01 s
0 to 5 s
0, 4, 9999
0
0.02 s
0 to 5 s
0 Hz
0 to 5 Hz
0
0, 1
110 %
0 to 400%
0
0 to 2
300 to 1200 V
760 V DC
0 to 5
0
0 to 590 Hz,
6 Hz
9999
100%
0 to 200%
9999
0 to 9999
9999
0 to 9999
9999
0 to 4, 9999
100%
30 to 150%
*2
Inverter
0.1 to 55 kW
rated
*3
0 to 3600 kW
current
0
0 to 3
9999
0, 1, 9999
Parameter Name
896
Power unit cost
Power saving monitor
897
average time
Power saving
898
cumulative monitor
clear
Operation time rate
899
(estimated value)
FM/CA terminal
900
calibration
AM terminal
901
calibration
Terminal 2 frequency
902
setting bias frequency
Terminal 2 frequency
902
setting bias
Terminal 2 frequency
903
setting gain frequency
Terminal 2 frequency
903
setting gain
Terminal 4 frequency
904
setting bias frequency
Terminal 4 frequency
904
setting bias
Terminal 4 frequency
905
setting gain frequency
Terminal 4 frequency
905
setting gain
Terminal 1 bias
917
frequency (speed)
917
Terminal 1 bias (speed)
Terminal 1 gain
918
frequency (speed)
Terminal 1 gain
918
(speed)
Terminal 1 bias
919
command (torque)
919
Terminal 1 bias (torque)
Terminal 1 gain
920
command (torque)
Terminal 1 gain
920
(torque)
Current output bias
930
signal
Current output bias
930
current
Current output gain
931
signal
Current output gain
931
current
Terminal 4 bias
932
command (torque)
Terminal 4 bias
932
(torque)
Terminal 4 gain
933
command (torque)
Terminal 4 gain
933
(torque)
PID display bias
934
coefficient
PID display bias
934
analog value
Setting Range
Initial Value
9999
0 to 500, 9999
9999
0 to 1000 h, 9999
9999
0, 1, 10, 9999
0 to 100%,
9999
9999
0 Hz
0 to 590 Hz
0 to 300%
0%
50 Hz
0 to 590 Hz
100%
0 to 300%
0 Hz
0 to 590 Hz
20%
0 to 300%
50 Hz
0 to 590 Hz
100%
0 to 300%
0 Hz
0 to 590 Hz
0%
0 to 300%
50 Hz
0 to 590 Hz
100%
0 to 300%
0%
0 to 400%
0%
0 to 300%
150%
0 to 400%
0 to 300%
100%
0%
0 to 100%
0%
0 to 100%
100%
0 to 100%
100%
0 to 100%
0 %
0 to 400%
20%
0 to 300%
150%
0 to 400%
100%
0 to 300%
9999
0 to 500, 9999
20%
0 to 300%