Parameter Name
PID display gain
935
coefficient
PID display gain
935
analog value
Input voltage mode
977
selection
Parameter copy alarm
989
release
990
PU buzzer control
PU contrast
991
adjustment
Operation panel
992
setting dial push
monitor selection
997
Fault initiation
PM parameter
998
Simple
Simple
Simple
initialization
Automatic parameter
999
Simple
Simple
Simple
setting
Direct setting
1000
selection
Lq tuning target
1002
current adjustment
coefficient
1006
Clock (year)
1007
Clock (month, day)
1008
Clock (hour, minute)
Emergency drive
1013
running speed after
retry reset
Integral stop selection
1015
at limited frequency
PTC thermistor
1016
protection detection
time
*2
For FR-F846-01160(55K) or lower
*3
For FR-F846-01800(75K) or higher
Setting Range
Initial Value
0 to 500, 9999
9999
100%
0 to 300%
0
0 to 2
*2
*2
10
10
*3
*3
100
100
1
0, 1
58
0 to 63
0 to 3, 5 to 14, 17,
18, 20, 23 to 25,
34, 38, 40 to 45,
0
50 to 57, 61, 62,
64, 67 to 69,
81 to 96, 98, 100
0 to 255, 9999
9999
0, 8009, 8109,
0
9009, 9109
1, 2, 10 to 13, 20,
9999
21, 9999
0
0 to 2
9999
50 to 150%, 9999
2000
2000 to 2099
101 to 131,
201 to 229,
301 to 331,
401 to 430,
501 to 531,
601 to 630,
101
701 to 731,
801 to 831,
901 to 930,
1001 to 1031,
1101 to 1130,
1201 to 1231
0 to 59,
100 to 159,
200 to 259,
300 to 359,
400 to 459,
500 to 559,
600 to 659,
700 to 759,
800 to 859,
900 to 959,
1000 to 1059,
1100 to 1159,
0
1200 to 1259,
1300 to 1359,
1400 to 1459,
1500 to 1559,
1600 to 1659,
1700 to 1759,
1800 to 1859,
1900 to 1959,
2000 to 2059,
2100 to 2159,
2200 to 2259,
2300 to 2359
50 Hz
0 to 590 Hz
0 to 2, 10 to 12
0
0 s
0 to 60 s
Parameter Name
Monitor with sign
1018
selection
Trace operation
1020
selection
1021
Trace mode selection
1022
Sampling cycle
Number of analog
1023
channels
1024
Sampling auto start
Trigger mode
1025
selection
Number of sampling
1026
before trigger
Analog source
1027
selection (1ch)
Analog source
1028
selection (2ch)
Analog source
1029
selection (3ch)
Analog source
1030
selection (4ch)
Analog source
1031
selection (5ch)
Analog source
1032
selection (6ch)
Analog source
1033
selection (7ch)
Analog source
1034
selection (8ch)
Analog trigger
1035
channel
Analog trigger
1036
operation selection
1037
Analog trigger level
Digital source
1038
selection (1ch)
Digital source
1039
selection (2ch)
Digital source
1040
selection (3ch)
Digital source
1041
selection (4ch)
Digital source
1042
selection (5ch)
Digital source
1043
selection (6ch)
Digital source
1044
selection (7ch)
Digital source
1045
selection (8ch)
1046
Digital trigger channel
Digital trigger
1047
operation selection
Display-off waiting
1048
time
1049
USB host reset
1106
Torque monitor filter
Running speed
1107
monitor filter
Excitation current
1108
monitor filter
BASIC OPERATION
Setting Range
Initial Value
0, 1, 9999
9999
0
0 to 4
0
0 to 2
2
0 to 9
4
1 to 8
0
0, 1
0
0 to 4
90%
0 to 100%
201
202
203
1 to 3, 5 to 14, 17,
18, 20, 23, 24, 34,
40 to 42, 52 to 54,
204
61, 62, 64,
67 to 69, 81 to 96,
205
98, 201 to 213,
230 to 232, 237,
238
206
207
208
1
1 to 8
0
0, 1
1000
600 to 1400
1
2
3
4
1 to 255
5
6
7
8
1
1 to 8
0
0, 1
0 min
0 to 60 min
0
0, 1
9999
0 to 5 s, 9999
9999
0 to 5 s, 9999
9999
0 to 5 s, 9999
29