4.4.4 Export Power Limit Connection Diagram
The methods of connecting the Power Limiting device CT is shown below.
For the detailed installation procedure of CT, please refer to Step 4 of 4.4.3.
white & Black Wire
CT
Black
Wire
L
Inverter
4.4.5 Earth Fault Alarm(Only for Australia and New Zealand)
In compliance with the section 13.9 of IEC62109-2, the GE P inverter is equipped with an
earth fault alarm. When earth fault occurs, the fault indicator at the front LED screen will light up. On
inverters with Wi-Fi communication, the system sends an email with the fault notification to the
customer. For inverters without Wi-Fi, the buzzer of the inverter will keep ringing for one minute and
ring again at 30-minute intervals until the fault is resolved. (This function is only available in Austra-
lia and New Zealand).
4.4.6 Monitoring Portal
Portal is an on-wire monitoring system. After completing the installation of commu-
nication connection, you can access portal.gesolarinverter.com or download the
'Power Sight' App by scanning the QR code to monitor your PV plant and device.
Please contact after-sales for further details.
15
15
N
Switch Board
Router
5 System Operation
5.1 LCD Panel
Green / green /green / red light respectively correspond to:
INDICATOR
Power Sight
STATUS
EXPLANATION
ON = INVERTER POWER-ON
OFF = INVERTER POWER-OFF
ON = INVERTER IS FEEDING POWER
OFF = INVERTER IS NOT FEEDING POWER
SINGLE SLOW FLASH = SELF CHECK BEFORE GRID CONNECT
SINGLE FLASH = WILL CONNECT WITH GRID
ON = COMMUNICATION SUCCESS
BLINK 2 = ROUTER COMMUNICATION FAILURE
BLINK 4 = SERVER COMMUNICATION FAILURE
BLINK = RS485 CONNECTED
ON = FAULT OCCURRED
OFF = NO FAULT