Electromagnetic flowmeter

Advertisement

Pulse output (available only for DO1, DO2):
Pulse rate:
Max 10kHz (10,000pps) (DO1)
Max 100Hz ( 100pps) (DO2)
(Over 1kpps, auto-setting)
Pulse width:
0.3 to 500ms (but less than half of the period
for 100% flow rate)
Note: The same and simultaneous pulse is
not available between DO1 and DO2.
Multi-range selection outputs (Note1):
High, High-high, Low, and/or Low-low alarm
Empty pipe alarm output (Note2):
Preset count output:
Converter failure alarm output (Note2):
Note1: Two outputs (DO1 and DO2) are
needed for 4-range switching and
forward/reverse 2-range switching.
Note2: Normal Open (default set) or
Normal Close is selected for alarm
outputs when programming. When
power failure occurs, unit will be
fault to Normal Open.
Communication signal:
HART (std.):
Digital signal is superimposed on 4-20mAdc
current signal as follows:
Conforms to HART protocol:
Load resistance: 240 to 750Ω
Load capacitance: 0.25µF maximum
Load inductance: 4mH maximum
PROFIBUS (opt.):
Protocol: PROFIBUS-PA
Baud rate: 31.25kbps
Bus voltage: 9 to 30Vdc
Consumption electric current of bus: 16mA or less
Profile: Profile Ver.3.01 for Process Control
Devices
Function blocks: AI (Flow) ×1, Totalizer ×1
Modbus (opt.):
Physical layer: RS485
Protocol: Modbus
Mode: RTU
Baud rate: 4800, 9600, 19200bps
Data length: 8bit
Parity bit: None, Odd, Even
Stop bit: 1bit or 2bit
Error check: CRC-16
Max. station number: 32 (with Master device)
Max. cable length: 1.2km (Note)
Note: This length is specification of 3 line
connection.
outputs (Note2):
LCD display:
Full
dot-matrix
128×128
(back-light provided)
Parameter setting:
Parameters can be set as follows:
IR Switches:
Tree
key
switches
configuration parameters.
Digital communication:
The AF900 hand-held terminal or PROFIBUS,
Modbus is needed to set parameters.
Zero adjustment:
Zero point adjustment can be started by pressing
the switch in the converter.
Damping:
0.5, 1 to 60 seconds (selectable in one second
increments)
Zero and span calibration:
Built-in calibration signal source allows converter
unit check.
Conditions when power fails:
Parameter setting values are stored in non-volatile
memory and the values will be restored when the
power returns to normal condition. The outputs and
display will remain as follows when power fails.
Current output: 0mAdc
Digital output: OFF
LCD display: No display
Communication: No communication
Power supply:
One of the following can be selected:
・100 to 240Vac, 50/60Hz (std.) (allowable voltage 80
to 264Vdc)
・24Vdc (allowable voltage 18 to 36Vdc)
・110Vdc (allowable voltage 90 to 130Vdc)
Surge protection:
Arresters are installed in the power supply, and
current signal output circuit.
Case:
Aluminum alloy (equivalent of IP67)
Coating:
Acrylic resin-baked coating, pearl-gray colored
Cable connection ports:
Cable glands: Provided as standard
Ouder diameter of cable φ9 to
Material Nylon 66
G (PF) 1/2 male screw.
Note: When PROFIBUS or Modbus options is
specified, cable gland size is φ6 to 8mm for
signal cable, φ9 to 14mm for power cable.
Applicable diameter:
0.354 to 0.551 inch (9 to 14mm)
EJL-146C
dot
LCD
display
are
provided
to
14mm
set
3