Download Print this page

Type Specification Code - Toshiba GF642 Manual

Electromagnetic flowmeter

Advertisement

Type Specification Code

Model number
1
2 3 4 5 6 7 8
G F 6 4 2
5 0
6 0
7 0
8 0
9 0
A 0
A 2
A 3
A 4
A 6
A 7
A 8
A 9
B 0
Code explanation ●: Standard ○:Option -: Not available
A : ANSI 150, AWWA class D,
B : EN1092-1PN6,10、GB9110 0.6,1.0MPa
*1 Meter size 20"(500mm), 24"(600mm) are ANSI 150, Meter size 28"(700mm) and over is AWWA class D.
Table4. Type specification code of detector
Specification code
9
1
1
1
1
0
1
2
3
A
F
C
G
H
N
K
C
F
A
B
1
Contents
1
4
Electromagnetic flowmeter detector
Meter size
500mm
600mm
700mm
800mm
900mm
1000mm
1200mm
1350mm
1400mm
1600mm
1650mm
1800mm
1950mm
2000mm
Connection flange standard
ANSI 150, AWWA class D *1
EN 1092-1 PN6 (DIN)
EN 1092-1 PN10 (DIN)
GB 9119 0.6MPa
GB 9119 1.0MPa
Lining
Natural rubber
Electrode material
AISI316L
Titanium
Hastelloy C equivalent
Roll prevention Base
Base not provided
Base provided
Standard
EJL-146C
A
B
9

Advertisement

loading

This manual is also suitable for:

Lf622