9.2 Type Specification Code

Model
1 2
3
4
5
L F 6 5
4
Size code explanation:
Note1: Range of ambient temperature is from -4 °F to 140 °F (-20 to +60C).
Note2: Consult Toshiba before ordering when choose materials at the wetting parts.
Note3: Separate type detector only.
Note4: Separate type detector only. Specifying the code "C", indicate the length of cables from 1 to 300m 1 meter increments.
Note5: Polyurethane lining is available to choose only in this specification.
Note6: Electrode is available for 316L stainless steel only and Grounding ring is available for 316/316L stainless steel only.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Table 9.3 Type Specification Code
Specification Code
6
7 8
9 10 11 12 13 14
D
E
S
F
G
W
H
J
U
K
L
M
N
P
Q
R
Mounting Style
L
M
1
C
D
1
2
B
C
D
E
F
C
N
Grounding Ring Material (Note 2)
C
D
E
F
G
H
Flow and calibration velocity range
A
B
C
Excitation and Signal Cables
A
B
C
Coating
F
C
D
E
Description
Flange type electromagnetic flowmeter detector
Usage
cFMus Division 2 Hazardous Location
Meter size
½"(15mm)
1"(25mm)
1¼"(32mm)
1½"(40mm)
2"(50mm)
2½"(65mm)
3"(80mm)
4"(100mm)
5"(125mm)
6"(150mm)
8"(200mm)
10"(250mm)
12"(300mm)
14"(350mm)
16"(400mm)
18"(450mm)
Detector/Converter combined type
Detector/Converter separate type
Detector/Converter separate type (Note 1)
Connection flange standard, Overall length
ANSI 150, ISO length
ANSI 300, ISO length
ANSI 150, Toshiba length
ANSI 300, Toshiba length
Electrode Material (Note 2)
316L stainless steel (Standard for Polyurethane lining)
Ti (titanium)
Pt-Ir (platinum/iridium)
Ta (tantalum)
Hastelloy C (Equivalent) (Standard for PFA lining)
Lining Materials (Note 2)
PFA (Standard for Hastelloy C electrode)
Polyurethane (NSF certified)
(Standard for 316L electrode) (Note 6)
316 stainless steel
316L stainless steel
Ti (titanium)
Ta (tantalum)
Pt-Ir (platinum/iridium)
Hastelloy C (Equivalent)
1.0 to 32.8 ft/s (standard range calibration)
1.0 to 32.8 ft/s (specified range calibration)
0.3 to 32.8 ft/s (specified range calibration)
not provided
30m cable, provided (Note 3)
other lengths, provided (Note 4)
PU coating pearl-gray colored
black tar epoxy resin 0.3mm
black tar epoxy resin 0.5mm
black tar epoxy resin 0.5mm for submersible type
(Note 5)
√ : Object
: Standard
− 42 −
6F8A0926
Detector category
Gr.-A
Gr.-B
: Option
–: Not available

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lf620f

Table of Contents