12 Hardware description
Frame size
Plus code
R8
-
R9
-

Special requirements

Frame size
R1
Insert a sealing plug and install an extra internal fan, or remove the front cover.
Reason for installing an extra fan is that the sealing plug will prevent cooling
R2
air flow from below to the control circuits of the drive. This fan is included in IP55
R3
(UL Type 12) drives as standard. For IP21 (UL Type 1 drives) it can be ordered
R4
with the codes given in section
Exception: In dry environment, you can leave the cover in place without
inserting the sealing plug.

Ordering codes

The flange mounting kit is a plus code option (+C135) or can be ordered with these
ordering codes separately.
Frame size Ordering code of flange mounting kit
R1
3AXD50000105311 (IP21, UL Type 1)
R2
3AXD50000105328 (IP21, UL Type 1)
R3
3AXD50000105335 (IP21 and IP55, UL Type 1 and UL Type 12)
R4
3AXD50000031460 (IP21, UL Type 1)
R5
3AXD50000031461 (IP21, UL Type 1)
R6
3AXD50000018852 (IP21, UL Type 1)
R7
3AXD50000018853 (IP21, UL Type 1)
R8
3AXD50000018854 (IP21, UL Type 1)
R9
3AXD50000018855 (IP21, UL Type 1)
Frame size
Ordering code of IP55 (UL Type 12) internal cooling fan for IP21 (UL Type 1)
drives
R1
3AXD50000050128
R2
3AXD50000050128
R3
3AUA0000088115
R4
3AXD50000034334
Degree of
protection
IP21 (UL Type 1)
IP20 (UL Open Type)
IP21 (UL Type 1)
IP20 (UL Open Type)
IP21 (UL Type 1)
Ordering codes
Degree of protection with flange
Front
IP55 (UL Type 12)
IP55 (UL Type 12)
below.
Back

Advertisement