Note: At an OC-N (N>1) node, the VT# may not indicate the actual
VT position in the OC-N signal. To find out which VT in the OC-N
signal corresponds to the displayed VT#, the user must refer to the
OC-N JMUX unit's TSI/CC information screen.
JMUX CHANNEL
Allows DS0 channel assignment to the unit. Channel number is
selectable from 1 to 24. A '-' (default selection) indicates that a
channel has not been assigned. Each channel occupies its own
DS0 (64 kb/s) time slot on the JVT.
Ensure that the channel assigned on this unit is not assigned on
any other DS0 level unit on the same JVT. The corresponding far-
end unit must be given the same channel assignment.
RACK NUMBER (use is optional)
Identifies the rack or cabinet (1 to 64) in which the unit is located.
This information may be utilized on the NMS (Network
Management System).
RACK MOUNT POSITION (use is optional)
Identifies the shelf (1 to 64) in which the unit is located.
information may be utilized on the NMS.
UNIT'S SHELF SLOT (use is optional)
Identifies the slot position within the shelf (1 to 15) in which the unit
is located. This information may be utilized on the NMS.
Ring # and Node # (Not Adjustable)
Displays the Ring # and Node # this unit is on.

Test Setup

BANTAM JACK ACCESS
May be set for Bridging or Splitting (default).
Bridging mode allows for monitoring of the circuit via bantam jacks
on the unit face plate.
Splitting mode disconnects the drop side of the circuit (upon
insertion of test jack) and allows tones to be injected and measured
for end-to-end or loopback testing.
Copyright  GE Multilin Inc. 2002
342-86400-445PS
Issue 4.0
October 2006
Page 88