Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear eye
instructions
protection
1. SAfETy
IF YoU ARe In AnY doUBT ABoUT eleCTRICAl SAFeTY ConSUlT A QUAlIFIed eleCTRICIAn.
9
only for use with 6 - 24 volt dC systems.
9
DO NOT apply voltage or current to the probe that exceeds the specified maximum of 24V dC.
8
DO NOT use with industrial 110V systems.
8
DO NOT use on any circuit directly or indirectly connected to AC lines or any other AC power source.
8
DO NOT use with any component or circuits of the ignition system.
8
Before using this device, check the vehicle's electrical wiring and disconnect any part or system sensitive to voltage and current pulses
9
such as air bags, electronic control modules, etc.
Always check your instructions and procedures indicated in the vehicle service manual before attempting to disconnect any part or
9
subsystem of the electrical circuit.
When not in use, store the meter carefully in a safe, dry, childproof location. Avoid extremes of temperature.
9
DO NOT use the unit around explosive gases, vapor or dust. When the power switch is operated (forwards or backwards), battery
8
current is conducted to the tip of the probe which may cause sparks when contacting ground or other certain circuits.
DO NOT use leads if damaged or if the wire is bared in any way.
8
DO NOT use this tester for any purpose other than that for which it has been designed.
8
DO NOT use the probe to supply battery voltage to any circuit or component either on or off the vehicle that has a different voltage
8
supply rating
2. INTRODUCTION
Comprehensive 6-24V dC test kit. Find bad earths, breaks in continuity and short circuits
quickly and easily. Can even power up components on and off the vehicle. Kit includes
flexible extension cable, crocodile clip, wire probe and back-probe.
3. OPERATION
3.1.
BASIC CONNECTIONS. (See fig.1) The probe (2) is screwed directly into the
tester body (1). To increase accessibility replace the probe (2) with
the extension lead (4). The other accessories, extension probe (3), Wire probe
(5) and crocodile clip (8) can then be plugged into the socket at the other end of
the extension lead.
3.2.
BASIC OPERATION. (See fig.2) When the rocker switch (11) is moved
forwards to the single bar position the probe will be connected directly to the
Red clamp (6). When the rocker switch (11) is moved backwards to the double
bar position the probe will be connected directly to the BLACK clamp (2). The
Auxiliary ground lead (9) is connected directly to the black clamp (7).
3.3.
QUICK SELf TEST. (See fig.2) Unroll the unit's cable. Attach the red clamp to
the positive terminal of the vehicle's battery. Attach the black clamp to
the negative terminal of the vehicle's battery.
3.3.1.
Press and hold down the rocker switch (11) in the forward, single bar position.
The led indicator should light Red.
3.3.2.
Press and hold down the rocker switch (11) in the backwards, double bar
position. The led indicator should light GReen.
3.3.3.
The unit is now ready to use. If the led indicator did not light, the cause may be
that the clamp connections are poor or the unit is damaged.
© Jack Sealey limited
AUTO PROBE EXCEL KIT 6 - 24v
PPLK
Model no:
Original Language Version
fig.1
1) Tester body 4) Extension lead
2) Probe
5) Wire probe
3) Extn. probe 6) Red (+) clamp
fig.2
PPLK Issue 3 12/02/19
7) Black (-) clamp
8) Crocodile clip
9) Ground lead

Advertisement

loading

Summary of Contents for Sealey PPLK

  • Page 1 PPLK Model no: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 The component requires a high amperage (e.g. a starter motor). NOTE: When the unit sounds, a circuit breaker within the unit will trip. This breaker will reset automatically within 3 to 5 seconds. Original Language Version PPLK Issue 3 12/02/19 © Jack Sealey limited...
  • Page 3 Important: no liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk...