nOTE: The unit is equipped with multiple spindle lock
detents allowing an optional "manual ratchet" method of
tightening the cutter.
To tighten with the manual ratchet method:
a. Without removing the wrench from the collet nut 
release pressure on the spindle lock button 
b. With the wrench still on the collet nut 
tightening direction to reset the wrench position.
c. Depress the spindle lock button 
wrench clockwise.
d. Repeat the procedure until the collet nut 
desired tightness.
NOTICE: Avoid possible damage to the collet. Never
tighten the collet without a cutter.
To Remove the Cutter
1. Remove the motor unit from the base unit, see Motor
Quick Release.
2. Depress the spindle lock button 
in place while turning the collet nut 
with the wrench provided.
To loosen using the manual ratchet method:
a. Without removing the wrench from the collet nut 
release pressure on the spindle lock button 
b. With the wrench still on the collet nut 
loosening direction to reset the wrench position.
c. Depress the spindle lock button 
wrench counterclockwise.
d. Repeat the procedure until the collet nut 
the cutter can be removed.
Collets
nOTE: Never tighten the collet without first installing a router
cutter in it. Tightening an empty collet, even by hand, can
damage the collet.
To change collet sizes, unscrew the collet assembly as described
above. Install the desired collet by reversing the procedure.
The collet and the collet nut are connected. Do not attempt to
remove the collet from the collet nut.
OPERATION
Instructions for Use

WARNING: Always observe the safety instructions and
applicable regulations.

WARNING: To reduce the risk of serious personal
injury, turn tool off and disconnect tool from power
source before making any adjustments or removing/
installing attachments or accessories. Be sure the
trigger switch is in the OFF position. An accidental start-up
can cause injury.

WARNING: Do not use router cutters with a diameter
in excess of 30 mm in this tool.
 21 
,
 5 
.
 21 
, reverse the
 5 
again and turn the
 21 
reaches
 5 
to hold the spindle shaft
 21 
counterclockwise
 21 
,
 5 
.
, reverse the
 21 
 5 
again and turn the
 21 
is loose and
Proper Hand Position (Fig. M)

WARNING: To reduce the risk of serious personal injury,
ALWAYS use proper hand position as shown.

WARNING: To reduce the risk of serious personal
injury, ALWAYS hold securely in anticipation of a
sudden reaction.
D26200
Proper hand position requires one hand to be wrapped around
the base as shown.
D26203, D26204
Proper hand position when using the plunge base requires one
hand on each of the plunge handles 
Starting and Stopping the Motor (Fig. A)

CAUTION: Before starting the tool, clear the work area
of all foreign objects. Also keep firm grip on tool to resist
starting torque.

CAUTION: To avoid personal injury and/or damage to
finished work, always allow the power unit to come to a
COMPLETE STOP before putting the tool down.
To turn unit on, depress the side of the dust-protected switch 
that reads ON and corresponds to the symbol "I. "
To turn the unit off, depress the side of the switch that reads OFF
and corresponds with the symbol "O. "
Locking Lever Adjustment (Fig. D)

WARNING: To reduce the risk of injury, turn unit
off and disconnect it from power source before
installing and removing accessories, before
adjusting or when making repairs. An accidental start-
up can cause injury.
Excessive force should not be used to clamp the locking lever.
Using excessive force may damage the base.
When the locking lever 
 9 
is clamped the motor should not
move in the base.
Adjustment is needed if the locking lever will not clamp without
excessive force or if the motor moves in the base after clamping.
To adjust the locking lever's clamping force:
1. Open the locking lever 
 9 
.
2. Using a hex wrench turn screw 
nOTE: Turning the screw clockwise tightens the lever, while
turning the screw counterclockwise loosens the lever.
Centering the Subbase (Fig. E)

WARNING: To reduce the risk of injury, turn unit
off and disconnect it from power source before
installing and removing accessories, before
adjusting or when making repairs. An accidental start-
up can cause injury.
If you need to adjust, change, or replace the subbase, a
centering tool is recommended, refer to Accessories. The
centering tool consists of a cone and a pin. To adjust the
subbase, follow the steps below.
EnGLIsH
 44 
as shown.
 4 
 19 
in small increments.