Toshiba APLEX4 Series Original Instruction page 12

Table of Contents

Advertisement

Service Manual
(4)
Cable protector
Protects the cables and air tubes from control unit to piston.
(5)
Test button connector
To connect the test button
Control unit cover
Protects the control unit. Uses 6 screws (8), contains the
screen window
(1)
and the keyboard window
regulators for the solenoid valves (7), the path for the cable
protector
(4)
and the test button
Connections
(6)
Light indicator connector (optional)
DIN connector to connect the external optional light indicator
Green/Connected, Red/Error, Orange/Working. The semaphore has a 1,5m cable to connect to other place
different than standard one (see image) for example can be moved to the top of the optional support column
(APLEX4-SC). If the semaphore is not used, those signals can be used to connect to a PLC.
(7)
External photo sensor connector
DIN connector to the photo sensor, to detect the coming product and depending the selected mode starts
print&apply cycle or apply signal
(6)
located on the control unit cover (10).
(6)
with the connector (5).
(2)
and the
(1)
Air input to air control unit
Through the air group (1). Ø8mm tube.
(2)
Signal connection to EX4 printer
To EX4 printer In/Out I/F, together with
power cable 220V-50Hz to the printer
(3)
Signal for: photo sensor for printing and
security signal (door open)
DIN connector for additional signals to
depending on selected configuration to
manage printing order and security signal
(door open) to stop all operations when
active
(4)
Additional I/O board (optional)
(5)
General power supply connection
AC inlet 220V-50Hz, to power all the system
(printer included). It has a switch and a red
LED indicator.
12