Toshiba APLEX4 Series Original Instruction page 14

Table of Contents

Advertisement

Service Manual
Notes:
There is a PTC limitation on power output. Once it is triggered needs some minutes to work
again.
Input circuit:
CN2 connector (upper right). Perimeter security and inhibition signals.
Pin Name
Description
1
V24
Power 24V (50 mA max)
2
GND
0V ground
3
INP-2
Perimeter security signal
4
INP-3
Init cycle signal (printing) when printing signal is separated of apply signal
Notes:
There is a PTC limitation on power output. Once it is triggered needs some minutes to work
again.
Input circuit:
Activation (ON state) is made connecting INP signal to GND using
a contact or a NPN signal from a photocell, inductive sensor, etc.
In this state max current is 5mA.
On the contrary or in open circuit the signal is considered
deactivated (OFF state).
Activation (ON state) is made connecting INP signal to GND using
a contact or a NPN signal from a photocell, inductive sensor, etc.
In this state max current is 5mA.
On the contrary or in open circuit the signal is considered
deactivated (OFF state).